| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 4080576-01 | 3 - Design Control Reference | 2 - Production Item | UNITED TECHNOLOGIES CORPORATION | 77445 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 47 | 4710 | 013741351 | T383-D | 21989 | F | M | 3 | Q | N | U | 0 | 16 Apr 1993 |
The item is an Aviation Critical Safety Item/Flight Safety Critical Aircraft Part ((ACSI/FSCAP).
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZH01 | 1 Mar 1997 | |||||||||||||||||||||||||||||
| YJ01 | 1 Mar 2004 | |||||||||||||||||||||||||||||
| WP01 | 1 Jun 2012 | |||||||||||||||||||||||||||||
| FXX5 | FXX4 | 2 | C | J | 1 May 2013 | |||||||||||||||||||||||||
Suitable for competitive acquisition for the first. time. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Design Unstable: Items determined by technical decision during the provisioning cycle, during introduction into logistic systems, or at time of item management coding, to be highly subject to either: (A) Design change of the item itself, or (B) Replacement of the item itself through modification of the applicable next-higher assembly. These items will be reviewed for recording when an IM is notified that the item is used by another service/agency, when the design becomes stabilized, or when the item has been in operational use for two years. In all cases these shall be reviewed by IM for IMC change no longer than two years after the IMC J assignment.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| C | AX | 0 | 5 Jun 1997 |
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
Defense Supply Center Columbus, Columbus, OH 43216-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SE | Q | 576 | Z | 9 | A | B | Z | J | 125850 | F | 61440 | MUFFER-EXHAUST-SYS-PIPE-ETC-SUB-6 |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
70
Metal and Metal Products, (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
100.2
No Variation. NMFC and UFCC Match.
Oklahoma City Air Logistics Center, 3001 Staff Drive, Tinker AFB, OK 73145-3303
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Aircraft engine equipment and parts
1
AIR FORCE ERRC XF3: Stock Fund (Except Munitions); NAVY: Perishable Subsistence Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
| Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
|---|---|---|---|---|---|---|---|---|---|---|---|
| P | P | 10 | 1 | 7.0 lbs | 42in x 11in x 6in | 1.604 cu ft |
| Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 00 | EA | NA | X | ED | 00 | B | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
MIL-DTL-17667, neutral wrapping paper
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.
No requirement.
Unit container provides level B packing protection.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| ARJD | Design Form | STRAIGHT |