4720-00-606-5197

HOSE ASSEMBLY,NONMETALLIC


4720-00-606-5197 (4720006065197, 006065197)
Part Number (1 listing): C31-15-1161
Summary

FSG 47 / FSC 4720

DEMIL: B

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4720-00-606-5197 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
C31-15-11613 - Design Control Reference2 - Production ItemEDGEWOOD CHEMICAL BIOLOGICAL CENTER  81361    CAGE 81361  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 4720-00-606-5197 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
474720006065197A542A020311X43BNU01 Jan 1963
Code Definitions

47

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Pipe, Tubing, Hose, and Fittings

4720

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Hose and Flexible Tubing

006065197

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4720-00-606-5197

A542A0

Federal Item Identification Guide (FIIG_4065)

20311

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 4720-00-606-5197 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4720-00-606-5197 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2AC011 Jul 1973
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

AC

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


U.S. Army Chemical Research, Development and Engineering Center Aberdeen Proving Ground, MD 21010-5423

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

11 Jul 1973

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4720-00-606-5197 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Q736Z9AVZW051140Z52350HOSE-NOI-TUBING
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Q

Less Than Carload (LCL_CD_2760)


70

736

Water Commodity Code (WRT_CMDTY_CD_9275)


Plumbing Supplies

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

V

Air Commodity Code (AIR_CMTY_HDLG_9215)


Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

051140

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

52350

Uniform Freight Classification (UFC_CD_MODF_3040)

HOSE-NOI-TUBING

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4720-00-606-5197 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKUUEnd Connection DesignSTRAIGHT 1ST END
CQBDBurst Test Pressure1000.0 POUNDS PER SQUARE INCH
AHNCConnection StylePLAIN OPTIONAL END 1ST END
AWLSConnection TypeTHREADED INTERNAL PIPE 1ST END
AAGRCross-Sectional Shape StyleROUND
ADJSExterior ColorNATURAL
CRDWHydrostatic Test Pressure500.0 POUNDS PER SQUARE INCH
CQGMMaximum Operating Pressure250.0 POUNDS PER SQUARE INCH
CRXXMeasuring Method And Length120.000 INCHES NOMINAL EXCLUDING END FITTINGS
MEDAMedia For Which DesignedAIR AND ALCOHOL, ETHYL AND FUEL/OIL, HYDROCARBON AND WATER SINGLE RESPONSE
ACKHMinimum Inside Bending Radius9.000 INCHES
CQJXNominal Thread Size1.000 INCHES 1ST END
CRJMOuter Covering Environmental ProtectionMILDEW RESISTANT AND OIL RESISTANT
ABKVOutside Diameter1.125 INCHES NOMINAL
AARXInside Diameter0.750 INCHES NOMINAL
CRWLInside Surface ConditionSMOOTH
CQCSLayer Composition And Location1ST LAYER BRAIDED TEXTILE YARN AND 2ND LAYER BRAIDED TEXTILE YARN AND OUTER LAYER RUBBER IMPREGNATED BRAIDED COTTON CORD
FEATSpecial FeaturesFURNISHED WITH A STRAINER AND STRAINER GUARD
CRSMVacuum In Torr304.8
ABJHTemp Rating-40.0 DEG FAHRENHEIT AND 250.0 DEG FAHRENHEIT SINGLE RESPONSE
AAJDThread Class2B 1ST END
AAJFThread DirectionRIGHT-HAND 1ST END
THSDThread Series DesignatorUNF 1ST END


Back to Top