4720-00-789-6556

HOSE ASSEMBLY,NONMETALLIC


4720-00-789-6556 (4720007896556, 007896556)
Part Numbers (4 listings): U2HL20-20PA90-47-1/2 | 20SW-20SF90-47-1-2 | F44871 | U2EL20-20PA900PEN47-1/2 |
Summary

FSG 47 / FSC 4720

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1962

Unit Weight: 7.3 lbs

Unit Size:

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4720-00-789-6556 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
U2HL20-20PA90-47-1/23 - Design Control Reference9 - No Longer UsedPARKER HANNIFIN CORP  13174    CAGE 13174  
20SW-20SF90-47-1-25 - Replaced / Discontinued9 - No Longer UsedANCHOR SWAN CORP  70434      
F448715 - Replaced / Discontinued9 - No Longer UsedPACCAR GOVERNMENT GROUP CO  45320      
20SW-20SF90-47-1-25 - Replaced / Discontinued9 - No Longer UsedVEYANCE TECHNOLOGIES, INC.  63906      
20SW-20SF90-47-1-25 - Replaced / Discontinued9 - No Longer UsedGOODYEAR TIRE AND RUBBER CO THE  73842    CAGE 73842  
U2EL20-20PA900PEN47-1/25 - Replaced / Discontinued9 - No Longer UsedPARKER HANNIFIN CORP  13174    CAGE 13174  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 4720-00-789-6556 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
474720007896556A542A020311X43ANU1 Jan 1962
Code Definitions

47

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Pipe, Tubing, Hose, and Fittings

4720

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Hose and Flexible Tubing

007896556

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4720-00-789-6556

A542A0

Federal Item Identification Guide (FIIG_4065)

20311

Item Naming Code (INC_4080)

1 Jan 1962

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 4720-00-789-6556 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
ZU011 Jul 1995
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 4720-00-789-6556 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
396AXU2HL20-20PA90-47-1/2  13174   CAGE/13174
4596AXBF44871  45320  
596AXB20SW-20SF90-47-1-2  63906  
4596AXB20SW-20SF90-47-1-2  70434  
596AXB20SW-20SF90-47-1-2  73842   CAGE/73842
596AXBU2EL20-20PA900PEN47-1/2  13174   CAGE/13174
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

AX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43216-5000

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4720-00-789-6556 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2AX04 May 1970
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

AX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43216-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

4 May 1970

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4720-00-789-6556 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
736Z9ABZW051140Z52350HOSE-NOI-TUBING
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


736

Water Commodity Code (WRT_CMDTY_CD_9275)


Plumbing Supplies

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

051140

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

52350

Uniform Freight Classification (UFC_CD_MODF_3040)

HOSE-NOI-TUBING

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 4720-00-789-6556 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APAE1AAA7.3 lbs
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
000000000EDQQO
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

AE

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Seal or plug all openings and preserve by Method 10.

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

7.3 lbs

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

00

Unit Container Code (UNIT_CTNR_CD_5166)


No requirement.

ED

Intermediate Container Code (INTMD_CTNR_CD_5167)


ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4720-00-789-6556 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKUUEnd Connection DesignELBOW 1ST END
AKUTEnd Flange ConstructionSOLID 1ST END
AECSBolt Hole Quantity4 1ST END
AHNXBolt Hole Diameter0.469 INCHES NOMINAL 1ST END
CQBDBurst Test Pressure800.0 POUNDS PER SQUARE INCH
ADUZCenter To Center Distance Between Bolt Holes Along Length2.312 INCHES NOMINAL 1ST END
ADUYCenter To Center Distance Between Bolt Holes Along Width1.094 INCHES NOMINAL 1ST END
AHNCConnection StylePLAIN W/ GASKET GROOVE (SAE FLANGED HEAD) 1ST END
AWLSConnection TypePLAIN FACE FLANGE 1ST END
AAGRCross-Sectional Shape StyleROUND
AFQNFlange Length3.125 INCHES NOMINAL 1ST END
CTCJFlange StyleDOUBLE OVAL (SAE SPLIT TYPE FLANGE) 1ST END
AGFFFlange Width2.782 INCHES NOMINAL 1ST END
ABKUFlange Thickness0.574 INCHES NOMINAL 1ST END
CRFYFlow Angle90.0 DEGREES 1ST END
CRDWHydrostatic Test Pressure400.0 POUNDS PER SQUARE INCH
CQGMMaximum Operating Pressure200.0 POUNDS PER SQUARE INCH
CRXXMeasuring Method And Length47.500 INCHES NOMINAL OVERALL
MEDAMedia For Which DesignedAIR AND FUEL/OIL, HYDROCARBON AND WATER SINGLE RESPONSE
ACKHMinimum Inside Bending Radius8.000 INCHES
CRJMOuter Covering Environmental ProtectionOIL RESISTANT AND WEATHERPROOF
ABKVOutside Diameter1.797 INCHES NOMINAL
AARXInside Diameter1.250 INCHES NOMINAL
CRWLInside Surface ConditionSMOOTH
CQCSLayer Composition And Location1ST LAYER BRAIDED TEXTILE YARN AND 2ND LAYER HELIX WIRE COIL AND 3RD LAYER BRAIDED TEXTILE YARN AND OUTER LAYER MOLDED RUBBER, SYNTHETIC
FEATSpecial FeaturesPERMANENT END FITTINGS
CRSMVacuum In Torr50.8
ABJHTemp Rating-40.0 DEG FAHRENHEIT AND 200.0 DEG FAHRENHEIT SINGLE RESPONSE


Back to Top
Back to Top