| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 49-6956-FLX | 3 - Design Control Reference | 2 - Production Item | KICKHAM BOILER INC. | 81253 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 47 | 4720 | 011210642 | A542A0 | 17972 | X | M | 3 | A | N | A | 30 Oct 1981 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| C056 | C055 | 0 | 0 | 1 Jul 2010 | ||||||||||||||||||||||||||
Not Established
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 30 Oct 1981 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
Commanding Officer, USCG Surface Force Logistics Center, Code 028, Mil Stop 25, 2401 Hawkins Point Road, Baltimore, MD 21226-5000
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Unclassified
1
ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions; MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions; NAVY: Field Activity Control Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I (60 Months (5.00-Years) ) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life.
U.S. Coast Guard
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AKUU | End Connection Design | STRAIGHT 1ST END |
| AKUU | End Connection Design | STRAIGHT 2ND END |
| AKUT | End Flange Construction | SOLID 1ST END |
| AKUT | End Flange Construction | SOLID 2ND END |
| ABKG | Bolt Circle Diameter | 7.500 INCHES NOMINAL 2ND END |
| ABKG | Bolt Circle Diameter | 9.500 INCHES NOMINAL 1ST END |
| AHNX | Bolt Hole Diameter | 0.625 INCHES NOMINAL 2ND END |
| AHNX | Bolt Hole Diameter | 0.750 INCHES NOMINAL 1ST END |
| AECS | Bolt Hole Quantity | 8 1ST END |
| AECS | Bolt Hole Quantity | 8 2ND END |
| CQBD | Burst Test Pressure | 250.0 POUNDS PER SQUARE INCH |
| AHNC | Connection Style | PLAIN 1ST END |
| AHNC | Connection Style | PLAIN 2ND END |
| AWLS | Connection Type | PLAIN FACE FLANGE 1ST END |
| AWLS | Connection Type | PLAIN FACE FLANGE 2ND END |
| AAGR | Cross-Sectional Shape Style | ROUND |
| AGAV | End Item Identification | SHIPS SERVICE DIESEL GENERATOR ONBOARD 270 FT COAST GUARD VESSELS |
| ADJS | Exterior Color | NATURAL |
| AEPR | Flange Outside Diameter | 11.000 INCHES NOMINAL 1ST END |
| CTCJ | Flange Style | ROUND W/ BOLT HOLES 1ST END |
| CTCJ | Flange Style | ROUND W/ BOLT HOLES 2ND END |
| AEPR | Flange Outside Diameter | 9.000 INCHES NOMINAL 2ND END |
| ABKU | Flange Thickness | 0.937 INCHES NOMINAL 2ND END |
| ABKU | Flange Thickness | 1.062 INCHES NOMINAL 1ST END |
| CQGM | Maximum Operating Pressure | 15.0 POUNDS PER SQUARE INCH |
| CRXX | Measuring Method And Length | 20.000 INCHES NOMINAL OVERALL |
| ADJL | Inner Conveying Tube Style | ANNULAR CLOSE-PITCH CORRUGATED |
| AARX | Inside Diameter | 6.000 INCHES NOMINAL |
| CQCS | Layer Composition And Location | OUTER LAYER BRAIDED CORROSION RESISTANT STEEL WIRE |
| ABKV | Outside Diameter | 6.500 INCHES NOMINAL |
| FEAT | Special Features | LIVE LENGTH 14.0 IN; 0.75 IN LATERAL MOTION; HOSE MATL T321 SS; BRAID MATL T304 SS; REDUCER MATL STEEL SCM40; FLANGES MATL NO 150 ANSI RF STEEL; END USE FLEX CONNECTION ON SS DIESEL GENERATOR FROM WASTE HEAT RECOVERY UNIT TO SS GENERATOR JACKET WATER PUMP |
| ABJH | Temp Rating | 250.0 DEG FAHRENHEIT SINGLE RESPONSE |