4730-00-722-0642

ADAPTER,STRAIGHT,PIPE TO TUBE


4730-00-722-0642 (4730007220642, 007220642)
Part Numbers (2 listings): B1622 | W1233 |
Summary

FSG 47 / FSC 4730

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Replacement NSN:

4730-00-988-9139

Replacement Date: 1 Feb 1973

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4730-00-722-0642 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
B16223 - Design Control Reference1 - Incomplete Part NumberAMERICAN NATIONAL STANDARDS  80204    CAGE 80204  
W12333 - Design Control Reference2 - Production ItemMUELLER BRASS  41947    CAGE 41947  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 4730-00-722-0642 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
474730007220642A080B003776X49ANU1 Jan 1963
Code Definitions

47

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Pipe, Tubing, Hose, and Fittings

4730

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Hose, Pipe, Tube, Lubrication, and Railing Fittings

007220642

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4730-00-722-0642

A080B0

Federal Item Identification Guide (FIIG_4065)

03776

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 4730-00-722-0642 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G72000C1 Apr 1991
G76000L1 Apr 1991
G88000C1 Apr 1991
ZC011 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG C - REFERENCE NUMBER | NSN 4730-00-722-0642 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
331475DB1622  80204   CAGE/80204
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4730-00-722-0642 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3AX01AX01 Feb 1973 4730009889139 6 Jun 1967
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

AX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43216-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

1 Feb 1973

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

4730-00-988-9139

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

6 Jun 1967

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4730-00-722-0642 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4730-00-722-0642 Submit RFQ
MRCDecoded RequirementClear Text Reply
MATTMaterialCOPPER ALLOY OVERALL
AWLSConnection TypeUNTHREADED INTERNAL TUBE 1ST END
AWLSConnection TypeTHREADED INTERNAL PIPE 2ND END
AHNCConnection StylePLAIN (PIPE) 2ND END
AAARNominal Pipe Size Accommodated0.250 INCHES 2ND END
CWFDNominal Outside Diameter Tube Accommodated0.625 INCHES 1ST END
THSDThread Series DesignatorNPT 2ND END
CQJXNominal Thread Size0.250 INCHES 2ND END
CWFKTubing Wall Nominal Thickness For Which Designed0.042 INCHES 1ST END
CWFRNominal Overall Length0.938 INCHES


Back to Top
Back to Top