4810-00-056-2304

VALVE,REGULATING,FLUID PRESSURE


4810-00-056-2304 (4810000562304, 000562304)
Part Numbers (3 listings): 114HS102-4 | 3A011-4 | 26C26608 |
Summary

FSG 48 / FSC 4810

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

Unit Weight: 1.0 lbs

Unit Size: 6in x 5in x 3.7in

Unit Pack Cube: 0.064 cu ft

Replacement NSN:

4810-00-913-4287

Replacement Date: 22 Aug 1966

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4810-00-056-2304 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
114HS102-41 - Source of Control Reference2 - Production ItemTHE BOEING COMPANY  77272    CAGE 77272  
3A011-43 - Design Control Reference2 - Production ItemARKWIN INDUSTRIES, INC.  98391    CAGE 98391  
114HS102-45 - Replaced / Discontinued2 - Production ItemTHE BOEING COMPANY  81205    CAGE 81205  
26C266085 - Replaced / Discontinued9 - No Longer UsedKAISER FLUID TECHNOLOGIES INC.  99215      
Code Definitions

1 - Source of Control Reference

Reference Number Category Code (DRN_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 4810-00-056-2304 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
484810000562304A2110027565X1ANA01 Jan 1963
Code Definitions

48

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Valves

4810

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Valves, Powered

000562304

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4810-00-056-2304

A21100

Federal Item Identification Guide (FIIG_4065)

27565

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 4810-00-056-2304 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZK011 Apr 1991
YB011 Feb 1994
ZU011 Jul 1995
ZR011 Aug 2012
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 4810-00-056-2304 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
1121CTA114HS102-4  77272   CAGE/77272
1321CTA3A011-4  98391   CAGE/98391
1521CTC114HS102-4  81205   CAGE/81205
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

1

Reference Number Category Code (RNCC_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

CT

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C

Reference Number Status Code (RNSC_2923)


The reference number originates from a descriptive technical document of the product, which may be used as a procurement document without restrictions. The NCAGE specified for this reference number identifies the originating organization or agency of the document but not the supply source of the item. NOTE: This code is to be allocated to reference numbers originating from generally available specifications/standards or to drawing numbers for which the Government has separate property rights or for which the author does not claim any property rights.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4810-00-056-2304 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
1HB02KE022 Aug 1966 4810009134287 28 Oct 1965
1HB02HB022 Aug 1966 4810009501723 28 Oct 1965
Code Definitions

1

Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

HB

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Naval Sea Systems Command, Washington, DC 20362-5101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

2

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KE

Originator of Replacement Standardization Decision (ORG_STDZN_DEC_9325)


Naval ICP, Philadelphia, PA 19111

22 Aug 1966

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

4810-00-913-4287

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

4810-00-950-1723

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

28 Oct 1965

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4810-00-056-2304 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
P594Z9AAZP127220X64490PRESSURE-REG-RED-RELIEF-VALVES-NOI1
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


P

Less Than Carload (LCL_CD_2760)


77.5

594

Water Commodity Code (WRT_CMDTY_CD_9275)


Pumps and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

A

Air Commodity Code (AIR_CMTY_HDLG_9215)


Supplies and equipment for aircraft and aerial targets, including aircraft and maintenance parts, aircraft accessories, aircraft instruments and laboratory test equipment, aerial targets and gliders, aircraft/missile technical order compliance kits, etc

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

127220

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

64490

Uniform Freight Classification (UFC_CD_MODF_3040)

PRESSURE-REG-RED-RELIEF-VALVES-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG W - PACKAGING DATA | NSN 4810-00-056-2304 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APB4111.0 lbs6in x 5in x 3.7in0.064 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00NAX10
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

B

Item Type Storage Code (ITM_TYP_STOR_5156)


Unheated General Purpose

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

1.0 lbs

Unit Pack Weight (UP_WT_5153)

6in x 5in x 3.7in

Unit Pack Size (UP_SZ_5154)

0.064 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

NA

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

10

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable container included in this table may be used (see J.4.9.1).


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4810-00-056-2304 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADQZEnd Connection Quantity3
AAFZBody MaterialALUMINUM ALLOY,MIL-A-8097 COMP 14S TEMPER T6
AAQLBody StyleTEE
ADQRCenter To Center Distance0.890 INCHES MINIMUM AND 0.910 INCHES MAXIMUM
AEWFFilterNOT INCLUDED
ACKMFirst End Connection TypeTHREADED INTERNAL BOSS
ACKNFirst End Style DesignatorGASKET SEAL
ACLKFirst End Thread Class3B
ACLLFirst End Thread DirectionRIGHT-HAND
ACLJFirst End Thread Size And Series/Type Designator9/16-18 UNJF
ADQVFlow Control Device MaterialSTEEL, AMS 5630
ADQUFlow Control DeviceDISK, PLUG TYPE
AEVZMaximum Inlet Pressure Rating3000.0 POUNDS PER SQUARE INCH
ACKLMedia For Which DesignedHYDROCARBON FUELS AND OILS
ADZJMounting FacilityUNTHD HOLES
AEVAOutlet Pressure Range+1350.0 TO 1700.0 POUNDS PER SQUARE INCH
AAJPOutside Surface TreatmentANODIZED, MIL-A-8625
AEVNRegulation TypeAUTOMATIC SINGLE STAGE
ACSHSeat MaterialSTEEL, AMS 5610
ACLRSecond End Relationship With First EndIDENTICAL
ADQTPacking MaterialRUBBER,MIL-P-25732
AEVRValve Loading MethodSPRING
AEVQValve Stem DesignSINGLE SEAT
AZKQTemp Rating-65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM
ACMXThird End Relationship With Preceding EndsIDENTICAL WITH FIRST END


Back to Top