Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
7U7383-2 | 3 - Design Control Reference | 2 - Production Item | WOODWARD, INC. | 60029 | ![]() |
215-22116-2 | 7 - Vendor Item Drawing Reference | 2 - Production Item | TRIUMPH AEROSTRUCTURES, LLC | 80378 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
48 | 4810 | 000597646 | A506H0 | 61929 | F | M | 4 | A | N | A | 0 | 8 Jun 1967 |
The item is an Aviation Critical Safety Item/Flight Safety Critical Aircraft Part ((ACSI/FSCAP).
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG may exist but technical data sufficient for preparation of a full descriptive method item identification could not be acquired after several follow-up actions during a 150-day suspense period. Includes such reasons as: Industry refuses to provide the technical data based on policy, restricted or proprietary rights, non-existence of technical data, etc. (This code cannot be used in submittals for National Item Identification Number (NIIN) assignment or reinstatement.)
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
N2R4 | NAXS | 2 | C | V | E | JA | GG | 1 Jun 1996 |
Suitable for competitive acquisition for the first. time. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
An activity within the Navy is providing depot maintenance support.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Fleet Readiness Center South East (FRC-SE), Jacksonville FL
Naval Inventory Control Point, Philadelphia, PA 19111û5098
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 1 | KE | 7U7383-2 | 60029 | ![]() | ||||||
3 | 7 | 2 | 1 | KE | D | 215-22116-2 | 80378 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Naval ICP, Philadelphia, PA 19111
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | GP | 0 | 19 Sep 1968 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Naval Inventory Control Point, Philadelphia, PA 19111-5098
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KE | P | 594 | Z | Z | A | A | Z | P | 127220 | X | 64490 | PRESSURE-REG-RED-RELIEF-VALVES-NOI |
Naval ICP, Philadelphia, PA 19111
77.5
Pumps and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Supplies and equipment for aircraft and aerial targets, including aircraft and maintenance parts, aircraft accessories, aircraft instruments and laboratory test equipment, aerial targets and gliders, aircraft/missile technical order compliance kits, etc
No special handling required.
No Variation. NMFC and UFCC Match.
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
No QUP
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | B | DR | 1 | 000 | 9.8 lbs | 12in x 8in x 8in | 0.463 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
89 | GB | BG | 0 | EC | 00 | O | E | Q | M |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
Unheated General Purpose
Preserve by Method 30 as follows: Each unit shall have all internal fluid-carrying passages, which are not prelubricated, filled with the specified preservative, allowing space for internal thermal expansion. If filling is not practical, the unit shall be internally fog-sprayed or flushed, then drained to the drip point. All ports, fittings, openings, etc., shall be capped or plugged with noncorrosive (noninteracting) metal caps or plugs conforming to NAS 847 or equivalent. All hydraulic preservative operating fluid used shall be filtered through a 3 micron absolute filter prior to being used as specified above. Exterior bare metal surfaces, subject to corrosion, shall be coated with compound conforming to MIL-PRF16173, Grade 2 or MIL-C-11796, Class 3. Unit shall be wrapped with a greaseproof wrap conforming to MIL-PRF-121 or equivalent; seal seams with ASTM-D5486 tape to effect a measure of waterproofness and prevent unwrapping. The unit must be adequately cushioned with material specified and placed in a grade V3c container fabricated in accordance with ASTM-D5118 (as a minimum), Style FOL or CSSC. All seams, corners, and manufacturer's joint shall be tape-sealed with two inch tape conforming to ASTM-D5486, Type III or IV.
Any suitable process that is not injurious to the item.
Preserve with normal operating lubricant
MIL-PRF-121, greaseproof, waterproof barrier
A-A-1898, Grade II, water resistant cellulosic cushioning
Not Applicable
ASTM-D5118, Type CF, Class domestic, corrugated fiberboard box.
No requirement.
Unit container is not an acceptable shipping container.
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
FEAT | Special Features | MANUALLY OPERATED,2 POSN,3 WAY HYDRAULIC VALVE,ALUM ALLOY BODY,4.30 IN.LG,2.75 IN.W,3.18 IN.H,OPERATING PRESSURE 3000 PSI,12.2 GPM FLOW,50 PSI MAX PRESSURE DROP AT 12.2 GPM,TEMP RANGE -60 DEG F TO 275 DEG F;FSC APPLICATION DATA:AIRCRAFT HYDRAULIC SYSTEM |