4810-00-542-4974

VALVE,SOLENOID


4810-00-542-4974 (4810005424974, 005424974)
Part Numbers (3 listings): AV220-181-1 | AV51-932 | AV51-932-1 |
Summary

FSG 48 / FSC 4810

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4810-00-542-4974 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
AV220-181-13 - Design Control Reference2 - Production ItemAUTOMATIC SWITCH COMPANY  04845    CAGE 04845  
AV51-9325 - Replaced / Discontinued9 - No Longer UsedAUTOMATIC SWITCH COMPANY  04845    CAGE 04845  
AV51-932-15 - Replaced / Discontinued9 - No Longer UsedAUTOMATIC SWITCH COMPANY  04845    CAGE 04845  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 4810-00-542-4974 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
484810005424974A046B010998X1ANU1 Jan 1963
Code Definitions

48

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Valves

4810

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Valves, Powered

005424974

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4810-00-542-4974

A046B0

Federal Item Identification Guide (FIIG_4065)

10998

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 4810-00-542-4974 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZZ
N9BC3HZGHHD1 Aug 2004
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 4810-00-542-4974 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
326AXAV220-181-1  04845   CAGE/04845
4595AXBAV51-932  04845   CAGE/04845
4596AXBAV51-932-1  04845   CAGE/04845
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

AX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43216-5000

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG G - FREIGHT DATA | NSN 4810-00-542-4974 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
658Z9AHZW051080Z29300FAUCETS-BIBCOCKS-GATES-VALVES
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

051080

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

29300

Uniform Freight Classification (UFC_CD_MODF_3040)

FAUCETS-BIBCOCKS-GATES-VALVES

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 4810-00-542-4974 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSJU1EA0
DSSMSJU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4810-00-542-4974 Submit RFQ
MRCDecoded RequirementClear Text Reply
MATTMaterialCOPPER ALLOY BODY
MATTMaterialPLASTIC FLOW CONTROL DEVICE
MATTMaterialCOPPER ALLOY SEAT
STYLStyle DesignatorSTRAIGHT THRU FLANGED ENDS
CWCFFace To Face Distance4.500 INCHES
CCFGValve Size0.750 INCHES
ADQUFlow Control DevicePISTON
MEDAMedia For Which DesignedWATER, FRESH 1ST RESPONSE
MEDAMedia For Which DesignedFUEL/OIL, HYDROCARBON 2ND RESPONSE
MEDAMedia For Which DesignedAIR 3RD RESPONSE
CQGMMaximum Operating Pressure100.0 POUNDS PER SQUARE INCH 1ST RESPONSE
CQGMMaximum Operating Pressure125.0 POUNDS PER SQUARE INCH 2ND RESPONSE
CQGMMaximum Operating Pressure150.0 POUNDS PER SQUARE INCH 3RD RESPONSE
AEHZMaximum Operating Temp212.0 DEG FAHRENHEIT SINGLE RESPONSE
AQLRValve Operation MethodSOLENOID
CSBHVoltage In Volts And Current Type115.0 DC
AMPSCurrent Rating In Amps0.230
ADSKFlow Control Device Normal Operation PositionCLOSED
AWLSConnection TypeFLANGE ALL ENDS
ARKNFlange ShapeROUND WITH HOLES ALL ENDS
CWCDNominal Outside Diameter3.812 INCHES ALL ENDS
CWCKNominal Thickness0.438 INCHES ALL ENDS
AECSBolt Hole Quantity8 ALL ENDS
CWCQBolt Hole Nominal Diameter0.562 INCHES ALL ENDS
CWCTBolt Circle Nominal Diameter2.688 INCHES ALL ENDS
CWDFFlange Face DesignPLAIN ALL ENDS
BBJXMounting PositionHORIZONTAL
ADZHRenewable Seat Ring TypeTHREADED


Back to Top
Back to Top