Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
553875 | 3 - Design Control Reference | 2 - Production Item | HAMILTON SUNDSTRAND CORPORATION | 73030 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
48 | 4810 | 008581692 | A504K0 | 46201 | F | 4 | 3 | Q | N | A | 1 Jan 1962 |
The item is an Aviation Critical Safety Item/Flight Safety Critical Aircraft Part ((ACSI/FSCAP).
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C126 | 0 | 0 | 5 | 1 Apr 1991 | ||||||||||||||||||||||||||
FXX4 | 0 | 0 | F | D | SX | FT | 1 Apr 1991 | |||||||||||||||||||||||
NAXS | 0 | 0 | 5 | E | KE | FT | GG | 1 Apr 1991 | ||||||||||||||||||||||
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZT01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 2008 | |||||||||||||||||||||||||||||
ZM01 | 1 Feb 2015 |
Not Established
Depot Reparable Component (Type II). This code identifies SICA managed depot reparable components assigned to another service which is responsible for the logistics functions of single submitter cataloger, acquisition and disposal authority, depot maintenance, and performs the wholesale stock, store, and issue functions and establishes, budgets, and funds the wholesale stock level requirement. Supply requirements will be submitted to the PICA on requisitions which are funded by a designated point within the SICA. Unserviceable SICA assets will normally be returned to the PICA for credit. The SICA will provide item/program data required by the PICA to meet the materiel support commitments. Normally, Military Interdepartmental Purchase Requests (MIPR) will not be requested by the PICA to support SICA NIMSC 5 requirements. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
An activity within the Air Force is providing depot maintenance support.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Naval ICP, Philadelphia, PA 19111
Oklahoma City Air Logistics Center (OC-ALC), Tinker AFB, OK
Naval Inventory Control Point, Philadelphia, PA 19111û5098
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TU | 0 | 1 | TU | 0 | 12 Jun 1969 | 4810008977308 | 5 May 0072 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
671 | Z | 9 | A | A | Z | P | 127220 | X | 64490 | PRESSURE-REG-RED-RELIEF-VALVES-NOI |
Aircraft Parts, To include Test/Tool Sets and Equipment (other than armament systems)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Supplies and equipment for aircraft and aerial targets, including aircraft and maintenance parts, aircraft accessories, aircraft instruments and laboratory test equipment, aerial targets and gliders, aircraft/missile technical order compliance kits, etc
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Oklahoma City Air Logistics Center, 3001 Staff Drive, Tinker AFB, OK 73145-3303
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
NAVY: (1) Iram program intensive management reparables (2) material (expendable ordnance) requiring lot and serial-# control but which is reported by serial-# only.
Commanding Officer, Department of Homeland Security, USCG Aviation Logistics Center, 1664 Weeksville Road, Elizabeth City, NC 27909
COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below depot (Inventory Control Point (ICP)) level; DLA: This item has been reviewed and a determination has been made that the item can be restored to a serviceable condition from an unserviceable condition at the depot level; NAVY: Resale-Brand Name Perishable Subsistence
Department of the Air Force
Department of the Navy
U.S. Coast Guard
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | S | A | 52 | 1 | 000 | 16.0 lbs | 12in x 12in x 15in | 1.300 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
49 | GB | FA | H | ED | 00 | O | 03 | E | Q | M |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 51 | 1 | 000 | 13.0 lbs | 14.5in x 14.5in x 16.5in | 2.007 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | X | NR | 00 | B | 19 | M |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Secondary Inventory Control Activity (SICA)
Heated General Purpose – Heated 40 F and above
Container, watervaporproof bag, sealed, container
Any suitable process that is not injurious to the item.
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Vendor's protective grease or oil coating
MIL-PRF-121, greaseproof, waterproof barrier
PPP-C-1120, Class A, water resistant bound fiber
2 inches thick
ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.
No requirement.
Unit container is not an acceptable shipping container.
Mehod 50
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
No requirement
As required to protect the item or elements of the package
PPP-B-1672, Type I, vertical star cushioning in reusable box.
No requirement.
Unit container provides level B packing protection.
Method 50 reusable container
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ATQR | Valve Quantity | 3 |
ADQZ | End Connection Quantity | 2 |
AWLS | Connection Type | FLANGE, ROUND W/O HOLES |
CWDF | Flange Face Design | PLAIN |
CCFG | Valve Size | 3.000 INCHES |
CQCJ | Maximum Operating Pressure And Media For Which Designed | 210.0 POUNDS PER SQUARE INCH AIR |
CRWH | Maximum Operating Temp And Media For Which Designed | 700.0 DEG FAHRENHEIT AIR |
AQLR | Valve Operation Method | SOLENOID |
TMQY | Furnished Items And Quantity | 1 TUBE |
FEAT | Special Features | MANUFACTURERS SUGGESTED NAME VALVE-PRESSURE REGULATING; AIR PRESSURE 45 PSIA RECOMMENDED MINIMUM, MAXIMUM 210 PSIA; SOLENOID RECOMMEND PER AN3101A12S3P; MOUNTING CLAMP MARMAN 16512-331 OR EQUIPVALENT; REGULATED PRESSURE 39PSIG; WEIGHT 7.1 LBS; CONSISTS OF THE FOLLOWING MAJOR VALVES, CONTROL VALVE P/N 553480 & VALVE ASSEMBLY - PRESSURE REGULATING P/N 553500; WEIGHT 7.1 LBS; MIMIMUM AIR PRESSURE RECOMMENDED 45 PSIA, MAX 210 PSIA; TEMP RANGE -65 TO 700 DEF FEH; MOUNTING CLAMP MARMAN 16512-331 NOT FURNISHED |
AGAV | End Item Identification | 9P10-4-9-3; 9P5-3-98-3 |