Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
RB15S5-24VDC | 3 - Design Control Reference | 2 - Production Item | PARKER-HANNIFIN CORPORATION | 81978 | ![]() |
RB15S5-24VDC | 3 - Design Control Reference | 9 - No Longer Used | PARKER-HANNIFIN CORPORATION | 93781 | ![]() |
1002700 | 7 - Vendor Item Drawing Reference | 2 - Production Item | TLD ACE CORPORATION | 00365 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
48 | 4810 | 012581042 | A046B0 | 10998 | X | K | A | N | A | 27 Jun 1987 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DGX1 | 3 | H | 1 Feb 2007 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 5 | ZZ | RB15S5-24VDC | 81978 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 27 Jun 1987 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE | 594 | Z | 9 | A | V | Z | W | 051080 | Z | 29300 | FAUCETS-BIBCOCKS-GATES-VALVES |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
Pumps and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 31 | 1 | AAA | 3.0 lbs | 0.100 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | X | E6 | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Waterproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
No requirement
As required to protect the item or elements of the package
Vendor's fiberboard box.
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AHNC | Connection Style | PLAIN (TUBE) ALL ENDS |
AWLS | Connection Type | UNTHREADED INTERNAL TUBE ALL ENDS |
AMPS | Current Rating In Amps | 0.670 |
ADSK | Flow Control Device Normal Operation Position | CLOSED |
ADQU | Flow Control Device | DIAPHRAGM |
MATT | Material | COPPER ALLOY BODY |
MATT | Material | PLASTIC POLYTETRAFLUOROETHYLENE FLOW CONTROL DEVICE AND GLASS FIBER FLOW CONTROL DEVICE |
CQGM | Maximum Operating Pressure | 500.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
AEHZ | Maximum Operating Temp | 240.0 DEG FAHRENHEIT SINGLE RESPONSE |
MEDA | Media For Which Designed | REFRIGERANT 12 1ST RESPONSE |
MEDA | Media For Which Designed | REFRIGERANT 22 2ND RESPONSE |
MEDA | Media For Which Designed | REFRIGERANT 500 3RD RESPONSE |
MEDA | Media For Which Designed | REFRIGERANT 502 4TH RESPONSE |
BBJX | Mounting Position | HORIZONTAL |
CWFD | Nominal Outside Diameter Tube Accommodated | 0.250 INCHES ALL ENDS |
CQCP | Inlet/Outlet Operating Pressure Differential | 1.0 POUNDS PER SQUARE INCH MINIMUM AND 300.0 POUNDS PER SQUARE INCH MAXIMUM |
FEAT | Special Features | O/AH4.375 IN.; O/ALG4.906IN.;O/AW4.375 IN.;SOLDER CONNECTIONS;PORT DIA.0.563 IN.;BONNET 1; SCREW,BODY BONNET 4; REPAIR KIT |
AQLR | Valve Operation Method | SOLENOID |
CSBH | Voltage In Volts And Current Type | 24.0 DC |
STYL | Style Designator | STRAIGHT THRU |
SUPP | Supplementary Features | USED ON B-1B OSE41AO1 |