| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 280070-3 | 3 - Design Control Reference | 2 - Production Item | MAROTTA CONTROLS, INC. | 99657 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 48 | 4820 | 000710829 | A21100 | 27565 | X | 4 | 3 | A | N | U | 6 Nov 1971 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FXGC | FXAX | 3 | H | Z | SX | 1 Aug 2004 | ||||||||||||||||||||||||
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 3 | 2 | 5 | AX | D | 280070-3 | 99657 | | ||||
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43216-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| C | AX | 0 | 2 Apr 1973 |
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
Defense Supply Center Columbus, Columbus, OH 43216-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AX | 594 | Z | 9 | A | B | Z | P | 127220 | X | 64490 | PRESSURE-REG-RED-RELIEF-VALVES-NOI |
Defense Supply Center Columbus, Columbus, OH 43216-5000
Pumps and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
AIR FORCE ERRC XF3: Stock Fund (Except Munitions); NAVY: Perishable Subsistence Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
ARMY: If condemned or uneconomically repairable, then dispose at direct support (ds) level; DLA: This item has been reviewed and a determination made that the item can be restored to a serviceable condition from an unserviceable condition at the organizational/field level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at the third echelon level; NAVY: (1) Fast-Moving 1I Cog Forms (2) Non-Perishable Provisions
Department of the Air Force
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| ADQZ | End Connection Quantity | 2 |
| AAFZ | Body Material | ALUMINUM ALLOY, QQ-A-225/6, ALLOY 2024, T4 |
| AAQL | Body Style | STRAIGHT THRU W/OFFSET |
| ADQL | Face To Face Distance | 2.000 INCHES NOMINAL |
| AEWF | Filter | NOT INCLUDED |
| ACKM | First End Connection Type | THREADED INTERNAL PIPE |
| ACKN | First End Style Designator | PLAIN |
| ACLL | First End Thread Direction | RIGHT-HAND |
| ACLJ | First End Thread Size And Series/Type Designator | 7/16-20 UNF |
| ADQV | Flow Control Device Material | STEEL, CORROSION RESISTING, QQ-S-763, CLASS 302, 303, 304, 305, 310, OR 316 |
| ADQU | Flow Control Device | PISTON, FREE TYPE |
| AEVZ | Maximum Inlet Pressure Rating | 3000.0 POUNDS PER SQUARE INCH |
| ACKL | Media For Which Designed | HYDRAULIC FLUID, MIL-H-5606 |
| ADZJ | Mounting Facility | BOLTS |
| ACSX | Offset Distance | 0.406 INCHES NOMINAL |
| AEWA | Outlet Pressure Setting | 1200.0 POUNDS PER SQUARE INCH |
| AEVP | Manual Control Method | SCREW |
| AEVN | Regulation Type | MANUAL SINGLE STAGE |
| AEVS | Remote Actuation Method | PISTON |
| ACSH | Seat Material | POLYAMIDE NYLON |
| ACLR | Second End Relationship With First End | IDENTICAL |
| AAJP | Outside Surface Treatment | ANODIZED |
| FEAT | Special Features | VENT PORT SIZE 0.250 |
| AEVQ | Valve Stem Design | SINGLE SEAT |
| AEVR | Valve Loading Method | SPRING |
| ABEP | Stem Material | STEEL, CORROSION RESISTING, QQ-S-763, CLASS 302, 303, 304, 305, 310, OR 316 |
| AZKQ | Temp Rating | -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |