Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
28300-8 | 3 - Design Control Reference | 2 - Production Item | HYDRO-AIRE, INC. | 81982 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
48 | 4820 | 005293936 | A506H0 | 61929 | X | 1 | B | N | A | 0 | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB | ||||||||||||||||||||||||||||||
ZA | ||||||||||||||||||||||||||||||
ZH | ||||||||||||||||||||||||||||||
ZK | ||||||||||||||||||||||||||||||
ZU | ||||||||||||||||||||||||||||||
ZW | ||||||||||||||||||||||||||||||
ZZ | ||||||||||||||||||||||||||||||
FXX4 | 3 | P | F | D | SX | FT | 1 Apr 1991 | |||||||||||||||||||||||
ZK01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YB01 | 1 Feb 1994 | |||||||||||||||||||||||||||||
ZH01 | 1 Mar 1997 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 2008 | |||||||||||||||||||||||||||||
ZM01 | 1 Feb 2015 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The rights to use the data needed to purchase this part from additional sources are not owned by the Government and cannot be purchased. Valid AMCs: 1, 2, 3, 4 and 5.
An activity within the Air Force is providing depot maintenance support.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Oklahoma City Air Logistics Center (OC-ALC), Tinker AFB, OK
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
593 | Z | 9 | A | V | Z | P | 127220 | X | 64490 | PRESSURE-REG-RED-RELIEF-VALVES-NOI |
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Naval Inventory Control Point, Philadelphia, PA 19111-5098
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Unclassified
1
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Oklahoma City Air Logistics Center, 3001 Staff Drive, Tinker AFB, OK 73145-3303
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items
Department of the Navy
Department of the Air Force
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADQZ | End Connection Quantity | 3 |
AGAV | End Item Identification | APPLICABLE T.O. 9H8-14-140-3 FIG 2; U/O CODE A |
CQRG | Body Material | ALUMINUM ALLOY |
AWLS | Connection Type | THREADED INTERNAL BOSS |
AMPS | Current Rating In Amps | 0.5 |
CBBL | Features Provided | CONTINUOUS DUTY AND MANUAL OVERRIDE |
CYGY | Flow Pattern Quantity | 3 |
CQCJ | Maximum Operating Pressure And Media For Which Designed | 3000.0 POUNDS PER SQUARE INCH HYDRAULIC FLUID, PETROLEUM BASE |
CRWH | Maximum Operating Temp And Media For Which Designed | 250.0 DEG FAHRENHEIT HYDRAULIC FLUID, PETROLEUM BASE |
CQJX | Nominal Thread Size | 0.750 INCHES |
FEAT | Special Features | MANUFACTURERS SUGGESTED NAME IS SOLENOID OPERATED THREE WAY SELECTOR VALVE; MEDIA FLUID MIL-H-5606; CURRENT CONSUMPTION 0.5 AMP, MAX AT 24 VDC; PRESSURE TO ACTUATE VALVE 100 PSIG MAXIMUM; PORT PER MS33649, 1/2 INCH TUBE CONNECTIONS; MOUNTING HOLES(3) 0.203 TO 0.228 INCH DIAMETER; ABMIENT TEMP RANGE -65 TO +250 DEG FEH; WT 1.31 LBS; MAJOR COMPONENT PARTS: PISTON AND SLEEVE ASSY 26028, PISTON 26025, SLEEVE 26027, BODY 25471-8, CURE DATED ITEMS FOR REPAIR PARTS KIT 9672483-10, REPAIR PARTS KIT 9672484-10 |
AQLR | Valve Operation Method | SOLENOID |
CSBH | Voltage In Volts And Current Type | 17.0 DC AND 30.0 DC |
CYGZ | Spool Position Quantity | 2 |
CYHB | Spool Quantity | 1 |
AAJD | Thread Class | 3B |
THSD | Thread Series Designator | UNJF |