Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
649X6-4 | 3 - Design Control Reference | 9 - No Longer Used | TELEDYNE INDUSTRIES INC | 86768 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
48 | 4820 | 008031222 | A046B0 | 05488 | X | 4 | 4 | A | N | U | 1 Jan 1962 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist but technical data sufficient for preparation of a full descriptive method item identification could not be acquired after several follow-up actions during a 150-day suspense period. Includes such reasons as: Industry refuses to provide the technical data based on policy, restricted or proprietary rights, non-existence of technical data, etc. (This code cannot be used in submittals for National Item Identification Number (NIIN) assignment or reinstatement.)
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DGX1 | 0 | 0 | 1 Jan 2007 |
Not Established
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 9 | 5 | SB | D | 649X6-4 | 86768 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | AX | 0 | 2 Apr 1973 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43216-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 594 | Z | Z | A | B | Z | P | 127220 | X | 64490 | PRESSURE-REG-RED-RELIEF-VALVES-NOI |
77.5
Pumps and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CQCY | Adjustable Pressure Range | +430.0/+650.0 POUNDS PER SQUARE INCH |
AHNC | Connection Style | PLAIN (TUBE) ALL ENDS |
AWLS | Connection Type | THREADED EXTERNAL TUBE 1ST END |
ADSU | Disk Loading Method | SPRING |
ADQU | Flow Control Device | POPPET |
CQGM | Maximum Operating Pressure | 3100.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
CWFD | Nominal Outside Diameter Tube Accommodated | 0.250 INCHES 1ST END |
CQJX | Nominal Thread Size | 0.437 INCHES 1ST END |
CSDC | Opening Pressure Setting | 430.0 POUNDS PER SQUARE INCH |
CQRB | Seat Angle | 37.5 DEGREES 1ST END |
AQLR | Valve Operation Method | AUTOMATIC |
STYL | Style Designator | ANGLE |
AAJD | Thread Class | 3A 1ST END |
AAJF | Thread Direction | RIGHT-HAND 1ST END |
THSD | Thread Series Designator | UNF 1ST END |
CMLP | Thread Quantity Per Inch | 20 1ST END |