4920-00-001-1749

FIXTURE,TEST,SERVO


4920-00-001-1749 (4920000011749, 000011749)
Part Number (1 listing): A51S62200-1
Summary

FSG 49 / FSC 4920

DEMIL: B

DEMIL INT: 3

HMIC: N

Date Created: 18 Sep 1972

Unit Weight: 135.0 lbs

Unit Size: 40in x 16in x 16in

Unit Pack Cube: 5.926 cu ft

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4920-00-001-1749 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
A51S62200-13 - Design Control Reference2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  61174    CAGE 61174  
A51S62200-13 - Design Control Reference2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  61174    CAGE 61174  
A51S62200-15 - Replaced / Discontinued9 - No Longer UsedNORTHROP GRUMMAN SYSTEMS CORPORATION  26512    CAGE 26512  
A51S62200-15 - Replaced / Discontinued9 - No Longer UsedNORTHROP GRUMMAN SYSTEMS CORPORATION  26512    CAGE 26512  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 4920-00-001-1749 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
4949200000117497777721BNU18 Sep 1972
Code Definitions

49

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Maintenance and Repair Shop Equipment

4920

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Aircraft Maintenance and Repair Shop Specialized Equipment

000011749

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4920-00-001-1749

77777

Item Naming Code (INC_4080)

18 Sep 1972

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

2

Type of Item Identification (TYP_II_4820)


Reference Item Identification

1

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name does not exist.

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG C - REFERENCE NUMBER | NSN 4920-00-001-1749 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325KEA51S62200-1  61174   CAGE/61174
3595KEBA51S62200-1  26512   CAGE/26512
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

KE

Reference Number Action Activity Code (RNAAC_2900)


Naval ICP, Philadelphia, PA 19111

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4920-00-001-1749 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
CGP611 Jun 1973
Code Definitions

C

Item Standardization Code (ISC_2650)


An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.

GP

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Naval Inventory Control Point, Philadelphia, PA 19111-5098

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

11 Jun 1973

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4920-00-001-1749 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KE
Code Definitions

KE

Originating Activity Code (ORIG_ACTY_CD_4210)


Naval ICP, Philadelphia, PA 19111

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 4920-00-001-1749 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNN32VU1XEA0
Code Definitions

N32

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Naval Inventory Control Point, Philadelphia, PA 19111-5098

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

X

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


NAVY: Special Program Reparables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 4920-00-001-1749 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
XPA101000135.0 lbs40in x 16in x 16in5.926 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000ADXF200B00QFM
Code Definitions

X

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Validated Correction

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

A

Item Type Storage Code (ITM_TYP_STOR_5156)


Heated General Purpose – Heated 40 F and above

10

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Physical protection

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

135.0 lbs

Unit Pack Weight (UP_WT_5153)

40in x 16in x 16in

Unit Pack Size (UP_SZ_5154)

5.926 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

AD

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Cushion, anchor, block or brace as required.

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

F2

Unit Container Code (UNIT_CTNR_CD_5166)


ASTM-D6251, Type III, Class 2, overseas cleated plywood box or ASTM-D6880, Class 2, heavy duty nailed wood box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

B

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level B packing protection.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

F

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.




Back to Top
Back to Top