4935-01-565-7133

TEST SET,GUIDED MISSILE INFRARED TRACKER


4935-01-565-7133 (4935015657133, 015657133)
Part Numbers (3 listings): 649800 | MIL-HDBK-300(ATS) | AN/GSM-416A |
Summary

FSG 49 / FSC 4935

DEMIL: D

DEMIL INT: 1

HMIC: N

Date Created: 4 Aug 2008

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4935-01-565-7133 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
6498003 - Design Control Reference2 - Production ItemL-3 COMMUNICATIONS CINCINNATI  80045    CAGE 80045  
MIL-HDBK-300(ATS)5 - Replaced / Discontinued1 - Incomplete Part NumberMIL-HDBK-300  1HBK1      
AN/GSM-416A5 - Replaced / Discontinued1 - Incomplete Part NumberJOINT ELECTRONICS TYPE DESIGNATION  80058    CAGE 80058  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 4935-01-565-7133 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
494935015657133T228-A62067XKDNAA04 Aug 2008
Code Definitions

49

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Maintenance and Repair Shop Equipment

4935

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Guided Missile Maintenance, Repair, and Checkout Specialized Equipment

015657133

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4935-01-565-7133

T228-A

Federal Item Identification Guide (FIIG_4065)

62067

Item Naming Code (INC_4080)

4 Aug 2008

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 4935-01-565-7133 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FGG400FDFR1 Aug 2008
ZB011 Dec 2010
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

D

Item Management Code (IMC_2744)


Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.

FRDSOR

Depot Source of Repair Codes (DSOR_0903)


Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA


FLIS - SEG C - REFERENCE NUMBER | NSN 4935-01-565-7133 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32CZZ649800  80045   CAGE/80045
514ZZAN/GSM-416A  80058   CAGE/80058
514ZZMIL-HDBK-300(ATS)  1HBK1  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

C

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing. The drawing is available for unlimited use but under the security measures specified for the level of security classification assigned. The drawing will be furnished only to qualified requesters by the activity identified by the RNAAC.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4935-01-565-7133 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59704 Aug 2008
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

4 Aug 2008

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4935-01-565-7133 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TK
Code Definitions

TK

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 4935-01-565-7133 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFLZJ71SEA0
Code Definitions

FLZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

7

Controlled Item Inventory Code (CIIC_2863)


Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).

1

Quantity Unit Pack (QUP_6106)


1

S

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC ND2: AF Equipment Management System (AFEMS); NAVY: Slow Demand Velocity Items (Consumables)

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4935-01-565-7133 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
ACYNAc Voltage Rating115.0 VOLTS NOMINAL
ACYRDc Voltage Rating28.0 VOLTS NOMINAL
AEJZDepth36.000 INCHES NOMINAL
ACZBFrequency Rating400.0 HERTZ NOMINAL
FCLSFunctional ClassificationDD-2.6
FTLDFunctional DescriptionPROVIDES LINE REPLACEABLE UNIT TEST CAPABILITY FOR THE FOR THE AN/AAR-44A AND -44B INFRARED WARNING, RECEIVER SETS; ISOLATES MALFUNCTIONS TO THE SHOP REPLACEABLE UNIT; PROVIDES INTERCONNECTION AND TEST STIMULI TO TEST THE AN/AAR-44A CONTROL DISPLAY UNIT 628100, SIGNAL PROCESSOR UNIT 628200-002, AND SENSOR UNIT 628300-002, 628300-003 AND 628300-004; SIMULATES SYSTEM INPUTS TO THE LRU LRU SIGNAL RESPONSES TO MAINTENANCE PERSONNEL
HGTHHeight21.000 INCHES NOMINAL
ANPZInclosure FeatureMULTIPLE ITEM W/CARRYING CASE
AKWAJoint Electronics Type Designation System Item NameTEST SET,GUIDED MISSILE INFRARED TRACKER
AKWBJoint Electronics Type Designation System Item Type NumberAN/GSM-416A
AEASMajor ComponentsCOMPUTER, TRANSIT CASE, STORM CASE, OSCILLOSCOPE, MULTIMETER, TEST SET, CABLE ASSEMBLIES, ADAPTERS
FEATSpecial FeaturesINCLUDES: PROTECTIVE CASE WITH CARRYING HANDLE AND REMOVABLE COVER; CABLES FOR INTERCONNECTING THE UTS WITH AN/AAR-44 EQUIPMENT TO BE TESTED AND WITH EXTERNAL TEST EQUIPMENT
ABGLWidth36.000 INCHES NOMINAL
AQXYTest Type For Which DesignedIR RECEIVER TESTS


Back to Top
Back to Top