5130-01-661-4047

GRINDER,ELECTRIC,PORTABLE


5130-01-661-4047 (5130016614047, 016614047)
Part Number (1 listing): 6089-30
Summary

FSG 51 / FSC 5130

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Mar 2017

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5130-01-661-4047 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
6089-303 - Design Control Reference2 - Production ItemMILWAUKEE TOOL & EQUIPMENT COMPANY  60903      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5130-01-661-4047 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
515130016614047A541N002523X45ANAA01 Mar 2017
Code Definitions

51

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Hand Tools

5130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Hand Tools, Power Driven

016614047

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5130-01-661-4047

A541N0

Federal Item Identification Guide (FIIG_4065)

02523

Item Naming Code (INC_4080)

1 Mar 2017

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

5

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist but lack of technical data and/or the press of time force temporary use of the partial descriptive or reference method.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5130-01-661-4047 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Mar 2017
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5130-01-661-4047 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43239ZD6089-30  60903  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 5130-01-661-4047 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
DF
Code Definitions

DF

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Tank Automotive Command, Warren, MI 48090

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5130-01-661-4047 Submit RFQ
MRCDecoded RequirementClear Text Reply
CXCYPart Name Assigned By Controlling AgencyLARGE ANGLE GRINDER
FEATSpecial FeaturesNO LOAD SPEED 6000 RPM; CORD TYPE 2-WIRE; CORD LENGTH 8 FEET; DOUBLE INSULATED; MULTI-PORT EXHAUST SYSTEM; MAXIMUM WATTS 3130MWO; NINE POSITION ROTATING HANDLE
ACDCCurrent TypeUNABLE TO DECODE OR UNABLE TO DECODE
ACUSAlternating Current Rating In AmpsUNABLE TO DECODE
ACUTDirect Current Rating In AmpsUNABLE TO DECODE
AHDQSpindle DiameterUNABLE TO DECODE
AMSEVoltage RatingUNABLE TO DECODE
AYBYWheel Diameter AccommodatedUNABLE TO DECODE AND UNABLE TO DECODE


Back to Top