5305-00-314-3541

THUMBSCREW


5305-00-314-3541 (5305003143541, 003143541)
Part Numbers (81 listings): S628 | 94PC83 | 99PC83 | BDE1S6505-63PC49 | BB38S6505-458449PC49 | BB61S65-967PC49 | CA68S6505-53PC49 | CB1S6505-68PC49 | CL119S6505-281248PC49 | CL49S65-1154ALT1 | AR5S65-54PC49 | BB35S6505-553404PC49 | A025S65-902PC49 | A026S65-902PC49 | AV7S65-911PC49 | AN1S65-932PC49 | AVP10S65-1033PC49 | AVP10S65-904PC49 | AVP10S65-1019ALT1PC49 | AGC5S6505-465002AGC5S6505-465002 | AGC7S6505-519287PC49 | AS12S6505-29ALT1PC49 | AS11S65-940ALT1PC49 | AM57S65-933PC49 | AVG6S65-905ALT1PC49 | AVG1S65-904PC49 | AG88S6505-848551PC49 | 5-1AALT1PC49 | 5-1ALT2PC49 | 4-1JPC49 | 4-1KPC49 | 4-1LPC49 | 4-1NPC49 | 4-1MALT1PC49 | 4-1PALT1PC49 | 4-1QPC49 | 4-1RPC49 | 4-1PC49 | 4-1TPC49 | 4-1SPC49 | 5-2ALT1PC49 | 5-2APC49 | 5-2BALT1PC49 | 5-2CPC49 | 5-2DPC49 | 5-2EALT1PC49 | 5-2FPC49 | 5-2GALT1PC49 | 5-2HPC49 | 5-2JPC49 | 5-2KPC49 | 5-2LPC49 | 5-2MPC49 | 5-2NPC49 | 5-2PPC49 | 5-2QPC49 | 5-2RALT1PC49 | 5-2TPC49 | 5-2SPC49 | 5-2UPC49 | 5-2VPC49 | 5-2XPC49 | 5-2WPC49 | 5-3NPC49 | 5-3PC49 | 5-2YPC49 | 5-2ZPC49 | 5-3BPC49 | 5-3CPC49 | 5-3DPC49 | 5-3FPC49 | 5-3EPC49 | 5-3GPC49 | 5-3JPC49 | 5-3KPC49 | 5-3MPC49 | 4-1BPC49 | 4-1CALT1PC49 | 4-1DPC49 | 4-1GPC49 | 4-1EPC49 |
Summary

FSG 53 / FSC 5305

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

Unit Weight: 0.2 lbs

Unit Size: None

Unit Pack Cube: 0.007 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5305-00-314-3541 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
S6283 - Design Control Reference2 - Production ItemTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
94PC835 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
99PC835 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
BDE1S6505-63PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
BB38S6505-458449PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
BB61S65-967PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
CA68S6505-53PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
CB1S6505-68PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
CL119S6505-281248PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
CL49S65-1154ALT15 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AR5S65-54PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
BB35S6505-553404PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
A025S65-902PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
A026S65-902PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AV7S65-911PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AN1S65-932PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AVP10S65-1033PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AVP10S65-904PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AVP10S65-1019ALT1PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AGC5S6505-465002AGC5S6505-4650025 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AGC7S6505-519287PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AS12S6505-29ALT1PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AS11S65-940ALT1PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AM57S65-933PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AVG6S65-905ALT1PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AVG1S65-904PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
AG88S6505-848551PC495 - Replaced / Discontinued9 - No Longer UsedNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
5-1AALT1PC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-1ALT2PC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1JPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1KPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1LPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1NPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1MALT1PC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1PALT1PC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1QPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1RPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1PC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1TPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1SPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2ALT1PC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2APC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2BALT1PC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2CPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2DPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2EALT1PC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2FPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2GALT1PC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2HPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2JPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2KPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2LPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2MPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2NPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2PPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2QPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2RALT1PC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2TPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2SPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2UPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2VPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2XPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2WPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-3NPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-3PC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2YPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-2ZPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-3BPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-3CPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-3DPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-3FPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-3EPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-3GPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-3JPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-3KPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
5-3MPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1BPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1CALT1PC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1DPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1GPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
4-1EPC495 - Replaced / Discontinued9 - No Longer UsedTHE DEWEY ELECTRONICS CORPORATION  47496    CAGE 47496  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5305-00-314-3541 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
535305003143541A003B006673X1ANU1 Jan 1963
Code Definitions

53

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Hardware and Abrasives

5305

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Screws

003143541

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5305-00-314-3541

A003B0

Federal Item Identification Guide (FIIG_4065)

06673

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5305-00-314-3541 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZW011 Nov 1998
N9BZN9ZD3RZGHHDHX1 Jun 2005
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

R

Acquisition Method Suffix Code (AMSC_2876)


The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HXCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Navy ICP, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5305-00-314-3541 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3321KZDS628  47496   CAGE/47496
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

KZ

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5305-00-314-3541 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
CKZ014 Apr 1970
Code Definitions

C

Item Standardization Code (ISC_2650)


An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.

KZ

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

14 Apr 1970

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5305-00-314-3541 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
713Z9ABZQ093460X48930BOLTS-NUTS-NOI-BBC-ZINC
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


713

Water Commodity Code (WRT_CMDTY_CD_9275)


Metal Hardware

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

Q

Less Than Truckload (CLAS_RTNG_CD_2770)


70

093460

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

48930

Uniform Freight Classification (UFC_CD_MODF_3040)

BOLTS-NUTS-NOI-BBC-ZINC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5305-00-314-3541 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSZU1EA0
DSSMSZU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5305-00-314-3541 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP101AAA0.2 lbs0.007 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XD3D300EQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

10

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Physical protection

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.2 lbs

Unit Pack Weight (UP_WT_5153)

0.007 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

D3

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

E

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5305-00-314-3541 Submit RFQ
MRCDecoded RequirementClear Text Reply
AASBFastener Length0.683 INCHES MINIMUM AND 0.693 INCHES MAXIMUM
AASLHead Diameter0.500 INCHES NOMINAL
AASUHead Height0.250 INCHES NOMINAL
AASKHead StyleKNURLED NO. 1
CRHCHole Configuration StyleWING
AAUBHole Diameter0.067 INCHES NOMINAL
ASXKHole Quantity6
BQDMHole TypeDRILLED
MATTMaterialCOPPER ALLOY OVERALL
AHYMNominal Thread Diameter0.125 INCHES
ABQJPoint StyleOVAL
SFTTSurface TreatmentNICKEL OVERALL
AAJFThread DirectionRIGHT-HAND
AAJDThread Class2A
AASAThread Length0.683 INCHES MINIMUM AND 0.693 INCHES MAXIMUM
CMLPThread Quantity Per Inch40
THSDThread Series DesignatorUNC


Back to Top
Back to Top