Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
NAS625-19 | 3 - Design Control Reference | 2 - Production Item | NATIONAL AEROSPACE STANDARDS | 80205 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
53 | 5306 | 008174990 | A003B0 | 15903 | X | 1 | A | N | U | 1 Jan 1962 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Mar 2003 | |||||||||||||||||||||||||||||
FXGI | FXKZ | 1 | G | Z | SX | 1 Aug 2004 | ||||||||||||||||||||||||
C918 | C911 | 1 | G | 1 Feb 2005 | ||||||||||||||||||||||||||
ZN01 | 1 Nov 2009 | |||||||||||||||||||||||||||||
ZC01 | 1 Nov 2010 | |||||||||||||||||||||||||||||
N9BZ | 1 | G | Z | GH | GG | GT | 1 Dec 2013 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Philadelphia, PA 19111û5098
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | KZ | 0 | 12 Jun 1972 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Philadelphia, Philadelphia, PA 19101
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
573 | Z | 9 | A | B | Z | W | 093486 | Z | 48950 | BOLTS-NUTS-OR-SCREWS--NOI--SUB-3- |
Bolts or Nuts (Iron or Steel), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | V | U | Q | Z | EA | 0 | |
DF | SMS | D | U | 1 | N | EA | 0 | |
DN | SMS | D | U | 1 | EA | 0 | ||
DS | SMS | D | U | 1 | N | EA | 0 | |
GP | SMS | D | U | 1 | EA | 0 |
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
100
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
Department of the Navy
Defense Logistics Agency
U.S. Coast Guard
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | AAA | 0.1 lbs | 0.007 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | 00 | 0 | D3 | D3 | 00 | E | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
No requirement
No requirement
Not Applicable
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AATC | Extended Washer Diameter | 0.521 INCHES MINIMUM AND 0.531 INCHES MAXIMUM |
AATD | Extended Washer Thickness | 0.072 INCHES MINIMUM AND 0.092 INCHES MAXIMUM |
AASB | Fastener Length | 1.744 INCHES MINIMUM AND 1.774 INCHES MAXIMUM |
AAUR | Grip Diameter | 0.3110 INCHES MINIMUM AND 0.3120 INCHES MAXIMUM |
ANEE | Grip Length | 1.177 INCHES MINIMUM AND 1.197 INCHES MAXIMUM |
CQFM | Hardness Rating | 39.0 ROCKWELL C MINIMUM OVERALL AND 43.0 ROCKWELL C MAXIMUM OVERALL |
AASU | Head Height | 0.338 INCHES MINIMUM AND 0.358 INCHES MAXIMUM |
AASK | Head Style | DOUBLE HEXAGON W/HOLE |
MDCL | Material Document And Classification | MIL-S-5000 MIL SPEC 1ST MATERIAL RESPONSE OVERALL OR MIL-S-6098 MIL SPEC 2ND MATERIAL RESPONSE OVERALL OR MIL-S-6049 MIL SPEC 3RD MATERIAL RESPONSE OVERALL OR MIL-S-8503 MIL SPEC 4TH MATERIAL RESPONSE OVERALL OR MIL-S-5626 MIL SPEC 5TH MATERIAL RESPONSE OVERALL |
MATT | Material | STEEL COMP E4340 OVERALL OR STEEL COMP 8735 OVERALL OR STEEL COMP 8740 OVERALL OR STEEL COMP 6150 OVERALL OR STEEL COMP 4140 OVERALL |
CQBC | Minimum Tensile Strength | 180000 POUNDS PER SQUARE INCH |
AHYM | Nominal Thread Diameter | 0.312 INCHES |
AATB | Width Between Flats | 0.368 INCHES MINIMUM AND 0.377 INCHES MAXIMUM |
ZZZK | Specification/Standard Data | 80205-NAS625 PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD |
STDC | Surface Treatment Document And Classification | NAS 672 ASSN STD SINGLE TREATMENT RESPONSE OVERALL |
SFTT | Surface Treatment | CADMIUM OVERALL |
AAJD | Thread Class | 3A |
AAJF | Thread Direction | RIGHT-HAND |
AASA | Thread Length | 0.547 INCHES MINIMUM AND 0.597 INCHES MAXIMUM |
THSD | Thread Series Designator | UNF |
CMLP | Thread Quantity Per Inch | 24 |