5306-01-004-1929

BOLT,SHOULDER


5306-01-004-1929 (5306010041929, 010041929)
Part Number (1 listing): 2057F139
Summary

FSG 53 / FSC 5306

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 29 May 1975

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5306-01-004-1929 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2057F1393 - Design Control Reference2 - Production ItemCURTISS-WRIGHT CONTROLS, INC  0AHP5    CAGE 0AHP5  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5306-01-004-1929 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
535306010041929A003B004905XM4ANA029 May 1975
Code Definitions

53

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Hardware and Abrasives

5306

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Bolts

010041929

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5306-01-004-1929

A003B0

Federal Item Identification Guide (FIIG_4065)

04905

Item Naming Code (INC_4080)

29 May 1975

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

4

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist but technical data sufficient for preparation of a full descriptive method item identification could not be acquired after several follow-up actions during a 150-day suspense period. Includes such reasons as: Industry refuses to provide the technical data based on policy, restricted or proprietary rights, non-existence of technical data, etc. (This code cannot be used in submittals for National Item Identification Number (NIIN) assignment or reinstatement.)

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5306-01-004-1929 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YJ
YW
YJ011 Apr 1991
YW011 Aug 2000
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5306-01-004-1929 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
321KE2057F139  0AHP5   CAGE/0AHP5
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

KE

Reference Number Action Activity Code (RNAAC_2900)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG G - FREIGHT DATA | NSN 5306-01-004-1929 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KE
Code Definitions

KE

Originating Activity Code (ORIG_ACTY_CD_4210)


Naval ICP, Philadelphia, PA 19111

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5306-01-004-1929 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9IVU1EA0
Code Definitions

S9I

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Troop Support, Philadelphia, PA 19111 ** No longer valid for input **

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5306-01-004-1929 Submit RFQ
MRCDecoded RequirementClear Text Reply
AASYDistance From Centerline To Flat0.247 INCHES MINIMUM AND 0.251 INCHES MAXIMUM
AASBFastener Length1.420 INCHES NOMINAL
CQFMHardness Rating26.0 ROCKWELL C MINIMUM OVERALL AND 32.0 ROCKWELL C MAXIMUM OVERALL
AASUHead Height0.019 INCHES MINIMUM AND 0.020 INCHES MAXIMUM
AASLHead Diameter0.655 INCHES NOMINAL
AASKHead StyleDEE CHAMFER
MATTMaterialSTEEL OVERALL
AHYMNominal Thread Diameter0.375 INCHES
MDCLMaterial Document And ClassificationAMS 5628 ASSN STD SINGLE MATERIAL RESPONSE OVERALL
AATNShoulder Diameter0.415 INCHES NOMINAL FIRST SHOULDER
AATXShoulder Length0.073 INCHES NOMINAL FIRST SHOULDER
CWYBShoulder ShapeROUND FIRST SHOULDER
AAJDThread Class3A
AASAThread Length0.600 INCHES NOMINAL
CMLPThread Quantity Per Inch24
THSDThread Series DesignatorUNF


Back to Top