Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
58A122A1678 | 3 - Design Control Reference | 2 - Production Item | NAVAIR AND NAVSEA MANAGED | 10001 | ![]() |
58A122C834-1 | 3 - Design Control Reference | 2 - Production Item | NAVAIR AND NAVSEA MANAGED | 10001 | ![]() |
5S3-1 | 3 - Design Control Reference | 2 - Production Item | ALCOA GLOBAL FASTENERS, INC. | 71286 | ![]() |
9072589 | 3 - Design Control Reference | 2 - Production Item | U S ARMY AVIATION AND MISSILE | 18876 | ![]() |
10034248-1 | 5 - Replaced / Discontinued | 2 - Production Item | U S ARMY AVIATION AND MISSILE | 18876 | ![]() |
10034246-1 | 5 - Replaced / Discontinued | 2 - Production Item | U S ARMY AVIATION AND MISSILE | 18876 | ![]() |
106100-1 | 5 - Replaced / Discontinued | 2 - Production Item | KONTRON AG | C1834 | ![]() |
5S3-1 | 5 - Replaced / Discontinued | 2 - Production Item | ALCOA FASTENING SYSTEMS | D0680 | ![]() |
5L.3251.001.78 | 5 - Replaced / Discontinued | 2 - Production Item | EADS DEUTSCHLAND GMBH | D1901 | ![]() |
12440638-6 | 5 - Replaced / Discontinued | 2 - Production Item | SAFRAN | F6151 | ![]() |
5S3-1 | 5 - Replaced / Discontinued | 2 - Production Item | ALCOA FIXATIONS SIMMONDS SAS | F0224 | ![]() |
5S3-1 | 5 - Replaced / Discontinued | 2 - Production Item | FAIRCHILD FASTENERS UK LTD | K1678 | ![]() |
5S3-1 | 5 - Replaced / Discontinued | 2 - Production Item | NSF CONTROLS LIMITED | U1943 | ![]() |
0117456X00 | 5 - Replaced / Discontinued | 2 - Production Item | MBDA FRANCE | F0555 | ![]() |
10313530-1 | 5 - Replaced / Discontinued | 2 - Production Item | U S ARMY TANK AUTOMOTIVE COMMAND | 19207 | ![]() |
238-003-050 | 5 - Replaced / Discontinued | 2 - Production Item | ELETTRONICA GMBH | C3141 | ![]() |
A/CS917681/000 | 5 - Replaced / Discontinued | 2 - Production Item | RAYTHEON SYSTEMS LTD | K0268 | ![]() |
917681/001 | 5 - Replaced / Discontinued | 2 - Production Item | RAYTHEON SYSTEMS LTD | K0268 | ![]() |
B11805 | 5 - Replaced / Discontinued | 2 - Production Item | MBDA UK LTD | K0967 | ![]() |
238-003-050 | 5 - Replaced / Discontinued | 2 - Production Item | ELETTRONICA SPA | A1997 | ![]() |
C123Z9C155 | 5 - Replaced / Discontinued | 2 - Production Item | SIEMENS SCHWEIZ AG | S3120 | ![]() |
FMC-008 | 5 - Replaced / Discontinued | 2 - Production Item | BAE SYSTEMS | K0978 | ![]() |
5800334-6000-576 | 5 - Replaced / Discontinued | 2 - Production Item | THALESELECTRONIC SYSTEMS GMBH | D8385 | ![]() |
WA9338 | 5 - Replaced / Discontinued | 9 - No Longer Used | NORTHROP GRUMMAN SYSTEMS CORPORATION | 92755 | ![]() |
GW5024AS2S | 5 - Replaced / Discontinued | 9 - No Longer Used | NORTHROP GRUMMAN SYSTEMS CORPORATION | 26512 | ![]() |
R66172B18386 | 5 - Replaced / Discontinued | 9 - No Longer Used | UNIFAB INDUSTRIES INC | 60144 | ![]() |
R65571-553-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | UNIFAB INDUSTRIES INC | 60144 | ![]() |
5S3-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | BAE SYSTEMS PLC | K1987 | ![]() |
106100-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | NORTHROP GRUMMAN SYSTEMS CORPORATION | 95542 | ![]() |
373-1093P1 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 49956 | ![]() |
30050780 | 5 - Replaced / Discontinued | 9 - No Longer Used | FAIRCHILD CAMERA AND INSTRUMENT CORP | 13989 | ![]() |
5S3-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | FEWKES JOS T AND CO | 07652 | ![]() |
993324-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 82577 | ![]() |
108686-2 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 37695 | ![]() |
74269040001 | 5 - Replaced / Discontinued | 9 - No Longer Used | KOLLSMAN, INC. | 89944 | ![]() |
719699-21 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 05869 | ![]() |
719699-021 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 05869 | ![]() |
1105700 | 5 - Replaced / Discontinued | 9 - No Longer Used | MONADNOCK COMPANY THE | 60119 | ![]() |
5083-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | NEW HAVEN MFG CORP | 26344 | ![]() |
575R179H02 | 5 - Replaced / Discontinued | 9 - No Longer Used | WESTINGHOUSE ELECTRIC CORP | 79500 | ![]() |
13225E0768-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | CECOM LR CENTER | 97403 | ![]() |
C4524-1051-4 | 5 - Replaced / Discontinued | 9 - No Longer Used | TRANE U.S. INC. | 60532 | ![]() |
575R179H02 | 5 - Replaced / Discontinued | 9 - No Longer Used | LONE STAR COTTON MILLS INC | 97642 | ![]() |
C2088433-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTERNATIONAL INC | 27914 | ![]() |
7700567-3 | 5 - Replaced / Discontinued | 9 - No Longer Used | C SYSTEMS LLC | 088A2 | ![]() |
28A5W3 | 5 - Replaced / Discontinued | 9 - No Longer Used | LOCKHEED MARTIN CORPORATION | 04236 | ![]() |
28A5W3 | 5 - Replaced / Discontinued | 9 - No Longer Used | LOCKHEED MARTIN CORPORATION | 38597 | ![]() |
553-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | ALCOA GLOBAL FASTENERS, INC. | 71286 | ![]() |
9M284-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | BOEING COMPANY, THE | 76301 | ![]() |
5LV3251-001-78 | 5 - Replaced / Discontinued | 9 - No Longer Used | EADS DEUTSCHLAND GMBH | D1901 | ![]() |
410578-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 96214 | ![]() |
SM-C-879419 | 5 - Replaced / Discontinued | 9 - No Longer Used | US ARMY COMMUNICATIONS & | 80063 | ![]() |
373-1093P1 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON TECHNICAL SERVICES COMPANY | 3B150 | ![]() |
10121467 | 6 - Informative Reference | 9 - No Longer Used | PAEAEESIKUNTA | A486G | ![]() |
13211E8386 | 7 - Vendor Item Drawing Reference | 2 - Production Item | CECOM LR CENTER | 97403 | ![]() |
HE128-0029-1001 | C - Advisory Reference | 1 - Incomplete Part Number | ROCKWELL INTERNATIONAL CORP | 89372 | ![]() |
39001-000E | C - Advisory Reference | 1 - Incomplete Part Number | HONEYWELL INTERNATIONAL INC | 27914 | ![]() |
GW502AS2S | C - Advisory Reference | 1 - Incomplete Part Number | NORTHROP GRUMMAN SYSTEMS CORPORATION | 26512 | ![]() |
A158825 | C - Advisory Reference | 1 - Incomplete Part Number | CEC VIBRATION PRODUCTS INC. | 09384 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Informative Reference. North Atlantic Treaty Organization (NATO) Stock Numbers (CAGE Code 99995), Production Equipment Codes (CAGE 99998), and DoD Ammunition Codes (CAGE Code 99999) which may be related to NSNs. (Reference numbers for the CAGE Codes cited above shall be coded RNVC 9.)
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
53 | 5310 | 005309963 | A022B0 | 15937 | X | 1 | A | N | A | 0 | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YW01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZE01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZK01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZN01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZS01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Sep 1998 | |||||||||||||||||||||||||||||
YD01 | 1 Sep 1998 | |||||||||||||||||||||||||||||
YA01 | 1 Sep 2000 | |||||||||||||||||||||||||||||
WB01 | 1 Feb 2005 | |||||||||||||||||||||||||||||
WP01 | 1 Aug 2005 | |||||||||||||||||||||||||||||
A919 | A187 | 1 | C | Z | CD | AJ | CT | CL | BF | 1 Apr 2006 | ||||||||||||||||||||
C918 | C004 | 1 | C | XH | 1 Apr 2006 | |||||||||||||||||||||||||
FXGI | FXKZ | 1 | C | Z | SX | 1 Apr 2006 | ||||||||||||||||||||||||
MC47 | MC10 | 1 | C | Z | PA | 1 Apr 2006 | ||||||||||||||||||||||||
N9BZ | NIZD | 1 | C | Z | GH | GT | KE | JB | HX | HD | 1 Apr 2006 | |||||||||||||||||||
S911 | S006 | 1 | C | Z | XN | 1 Apr 2006 | ||||||||||||||||||||||||
BGX1 | 1 | C | 1 Dec 2006 | |||||||||||||||||||||||||||
WU01 | 1 Feb 2008 | |||||||||||||||||||||||||||||
WF01 | 1 May 2009 | |||||||||||||||||||||||||||||
WI01 | 1 Jan 2010 | |||||||||||||||||||||||||||||
WR01 | 1 Jan 2012 | |||||||||||||||||||||||||||||
ZT01 | 1 Oct 2012 | |||||||||||||||||||||||||||||
ZM01 | 1 Feb 2015 | |||||||||||||||||||||||||||||
YK01 | 1 Feb 2015 | |||||||||||||||||||||||||||||
YS01 | 1 Feb 2015 | |||||||||||||||||||||||||||||
YC01 | 1 Jul 2015 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000
Naval ICP, Philadelphia, PA 19111
Naval ICP, Mechanicsburg, PA 17055-0788
Navy ICP, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
U.S. Army Soldier's Biological and Chemical, Command, Natick, MA 01760
U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
USCG Aircraft Repair and Supply Center, Elizabeth City, NC 27909-5001
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | X | KZ | D | 58A122A1678 | 10001 | ![]() | ||||
3 | 3 | 2 | X | KZ | D | 58A122C834-1 | 10001 | ![]() | ||||
3 | 3 | 2 | X | KZ | D | 9072589 | 18876 | ![]() | ||||
3 | 3 | 2 | X | KZ | D | 5S3-1 | 71286 | ![]() | ||||
3 | 5 | 2 | 1 | KZ | D | 10313530-1 | 19207 | ![]() | ||||
3 | 5 | 2 | 3 | KZ | D | 238-003-050 | A1997 | ![]() | ||||
3 | 5 | 2 | 1 | KZ | D | 10034246-1 | 18876 | ![]() | ||||
3 | 5 | 2 | 1 | KZ | D | 10034248-1 | 18876 | ![]() | ||||
5 | 2 | 6 | ZG | 5800334-6000-576 | D8385 | ![]() | ||||||
4 | 5 | 2 | 4 | ZF | B | 5S3-1 | F0224 | ![]() | ||||
4 | 5 | 2 | 4 | ZF | C | 0117456X00 | F0555 | ![]() | ||||
4 | 5 | 2 | 6 | ZF | B | 12440638-6 | F6151 | ![]() | ||||
4 | 5 | 2 | 2 | ZK | D | 917681/001 | K0268 | ![]() | ||||
4 | 5 | 2 | 2 | ZK | D | A/CS917681/000 | K0268 | ![]() | ||||
1 | 5 | 2 | 2 | ZK | D | B11805 | K0967 | ![]() | ||||
1 | 5 | 2 | 2 | ZK | D | FMC-008 | K0978 | ![]() | ||||
4 | 5 | 2 | 3 | ZG | D | 5S3-1 | K1678 | ![]() | ||||
4 | 5 | 2 | 3 | ZG | A | 106100-1 | C1834 | ![]() | ||||
4 | 5 | 2 | 3 | ZG | A | 238-003-050 | C3141 | ![]() | ||||
4 | 5 | 2 | 1 | ZG | A | 5S3-1 | D0680 | ![]() | ||||
4 | 5 | 2 | 5 | ZG | A | 5L.3251.001.78 | D1901 | ![]() | ||||
3 | 5 | 2 | 3 | ZG | D | C123Z9C155 | S3120 | ![]() | ||||
4 | 5 | 2 | 2 | ZK | A | 5S3-1 | U1943 | ![]() | ||||
4 | 5 | 9 | 9 | ZG | B | 5LV3251-001-78 | D1901 | ![]() | ||||
4 | 5 | 9 | 2 | ZK | B | 5S3-1 | K1987 | ![]() | ||||
3 | 5 | 9 | 1 | KZ | B | 30050780 | 13989 | ![]() | ||||
3 | 5 | 9 | X | KZ | D | 28A5W3 | 04236 | ![]() | ||||
3 | 5 | 9 | 6 | KZ | B | 719699-021 | 05869 | ![]() | ||||
3 | 5 | 9 | 6 | KZ | B | 719699-21 | 05869 | ![]() | ||||
3 | 5 | 9 | 1 | KZ | B | 5S3-1 | 07652 | ![]() | ||||
5 | 9 | 5 | KZ | B | 7700567-3 | 088A2 | ![]() | |||||
4 | 5 | 9 | 1 | KZ | B | C2088433-1 | 27914 | ![]() | ||||
3 | 5 | 9 | X | KZ | B | 108686-2 | 37695 | ![]() | ||||
3 | 5 | 9 | X | KZ | B | 28A5W3 | 38597 | ![]() | ||||
5 | 9 | 2 | 9Z | B | 373-1093P1 | 3B150 | ![]() | |||||
4 | 5 | 9 | 2 | 9Z | B | 373-1093P1 | 49956 | ![]() | ||||
5 | 9 | A | ZZ | B | 1105700 | 60119 | ![]() | |||||
5 | 9 | 5 | KZ | B | R65571-553-1 | 60144 | ![]() | |||||
5 | 9 | 6 | KZ | B | R66172B18386 | 60144 | ![]() | |||||
3 | 5 | 9 | 1 | KZ | B | C4524-1051-4 | 60532 | ![]() | ||||
3 | 5 | 9 | X | KZ | D | 553-1 | 71286 | ![]() | ||||
5 | 9 | A | AJ | B | 13225E0768-1 | 97403 | ![]() | |||||
3 | 5 | 9 | X | KZ | B | 575R179H02 | 97642 | ![]() | ||||
3 | 5 | 9 | X | KZ | B | 74269040001 | 89944 | ![]() | ||||
3 | 5 | 9 | X | KZ | B | WA9338 | 92755 | ![]() | ||||
3 | 5 | 9 | X | KZ | B | 106100-1 | 95542 | ![]() | ||||
3 | 5 | 9 | X | KZ | B | 410578-1 | 96214 | ![]() | ||||
3 | 5 | 9 | X | KZ | D | 5083-1 | 26344 | ![]() | ||||
4 | 5 | 9 | 1 | KZ | B | GW5024AS2S | 26512 | ![]() | ||||
5 | 9 | 1 | KE | B | 9M284-1 | 76301 | ![]() | |||||
3 | 5 | 9 | X | KZ | B | 575R179H02 | 79500 | ![]() | ||||
5 | 9 | 1 | ZZ | B | SM-C-879419 | 80063 | ![]() | |||||
5 | 9 | A | KZ | B | 993324-1 | 82577 | ![]() | |||||
4 | 6 | 9 | 9 | WF | B | 10121467 | A486G | ![]() | ||||
4 | 7 | 2 | 1 | KZ | D | 13211E8386 | 97403 | ![]() | ||||
C | 1 | 5 | ZZ | AC | HE128-0029-1001 | 89372 | ![]() | |||||
C | 1 | 5 | ZZ | AC | GW502AS2S | 26512 | ![]() | |||||
C | 1 | 5 | ZZ | AC | 39001-000E | 27914 | ![]() | |||||
C | 1 | 5 | ZZ | AC | A158825 | 09384 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
DAC not known. Found on U.S. NSNs that were assigned before 1975. Cannot be used for new item assignment, or any maintenance action on older NSNs.
Defense Supply Center Philadelphia, Philadelphia, PA 19101
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Germany
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
France
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
The reference number originates from a descriptive technical document of the product, which may be used as a procurement document without restrictions. The NCAGE specified for this reference number identifies the originating organization or agency of the document but not the supply source of the item. NOTE: This code is to be allocated to reference numbers originating from generally available specifications/standards or to drawing numbers for which the Government has separate property rights or for which the author does not claim any property rights.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
United Kingdom
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is of the type for which an indication of document availability is not required.
DLIS-K, Battle Creek, MI 49037-3084
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
USA
U.S. Army Soldier's Biological and Chemical, Command, Natick, MA 01760
Naval ICP, Philadelphia, PA 19111
Informative Reference. North Atlantic Treaty Organization (NATO) Stock Numbers (CAGE Code 99995), Production Equipment Codes (CAGE 99998), and DoD Ammunition Codes (CAGE Code 99999) which may be related to NSNs. (Reference numbers for the CAGE Codes cited above shall be coded RNVC 9.)
Finland
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
Navy
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 96 | 0 | 25 Dec 1995 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
713 | Z | 9 | A | B | Z | U | 194160 | X | 55210 | WASHER-OR-GASKETS--IRON-OR-STEEL- |
Metal Hardware
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
50
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | D | U | 1 | Z | HD | 0 | |
DF | SMS | D | U | 1 | N | HD | 0 | |
DM | SMS | D | U | 1 | Z | HD | 0 | |
DN | SMS | D | U | 1 | HD | 0 | ||
DS | SMS | D | U | 1 | N | HD | 0 | |
GP | SMS | D | U | 1 | HD | 0 |
Defense Logistics Agency, Enterprise Business Systems
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Hundred - One hundred (100) of an item.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
U.S. Coast Guard
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | AAA | 0.1 lbs | 0.001 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | 00 | 0 | 10 | 00 | E | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
No requirement
No requirement
Not Applicable
Any suitable container included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ABMF | Distance Across Split Opening | 0.015 INCHES MINIMUM AND 0.035 INCHES MAXIMUM |
AAUB | Hole Diameter | 0.149 INCHES MINIMUM AND 0.156 INCHES MAXIMUM |
ABPX | Material Thickness | 0.012 INCHES MINIMUM AND 0.016 INCHES MAXIMUM |
MATT | Material | STEEL OVERALL |
ABKV | Outside Diameter | 0.264 INCHES MINIMUM AND 0.271 INCHES MAXIMUM |
STYL | Style Designator | SPLIT |
STDC | Surface Treatment Document And Classification | QQ-P-416,TY 2,CL A FED SPEC SINGLE TREATMENT RESPONSE OVERALL |
SFTT | Surface Treatment | CADMIUM OVERALL AND CHROMATE OVERALL |