Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
FFW100 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | FEDERAL SPECIFICATIONS | 81348 | ![]() |
FFW100 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | FEDERAL SPECIFICATIONS | 81348 | ![]() |
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
53 | 5310 | 005791591 | A022B0 | 14218 | X | 1 | A | N | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 4 | 1 | 3 | 75 | D | FFW100 | 81348 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
GSA, FSS/FCSC Washington, DC 20406
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | KZ | 6 | 1 | KZ | 0 | 11 Jul 1968 | 5310006163554 | 11 Jul 1968 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Philadelphia, Philadelphia, PA 19101
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CQFM | Hardness Rating | 40.0 ROCKWELL C MINIMUM AND 50.0 ROCKWELL C MAXIMUM |
AAUB | Hole Diameter | 0.115 INCHES MINIMUM AND 0.123 INCHES MAXIMUM |
ABPX | Material Thickness | 0.015 INCHES MINIMUM AND 0.019 INCHES MAXIMUM |
MATT | Material | STEEL COMP 1050 OVERALL OR STEEL COMP 1551 OVERALL OR STEEL COMP 1552 OVERALL OR STEEL COMP 1053 OVERALL OR STEEL COMP 1054 OVERALL OR STEEL COMP 1055 OVERALL OR STEEL COMP 1059 OVERALL OR STEEL COMP 1060 OVERALL OR STEEL COMP 1561 OVERALL OR STEEL COMP 1064 OVERALL |
ZZZT | Nondefinitive Spec/Std Data | 2 TYPE AND 1 STYLE AND 1 COMPOSITION |
ABKV | Outside Diameter | 0.275 INCHES MINIMUM AND 0.290 INCHES MAXIMUM |
STYL | Style Designator | FLAT EXTERNAL TEETH |
STDC | Surface Treatment Document And Classification | QQ-P-416,TY 2,CL 3 FED SPEC SINGLE TREATMENT RESPONSE OVERALL |
SFTT | Surface Treatment | CADMIUM OVERALL |
TEST | Test Data Document | 81348-FFW100 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |