5310-00-792-4797

NUT,SELF-LOCKING,PLATE


5310-00-792-4797 (5310007924797, 007924797)
Part Numbers (2 listings): R407P1B | LHTA517-2860-02 |
Summary

FSG 53 / FSC 5310

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 9 Aug 1968

Replacement NSN:

5310-00-779-3601

Replacement Date: 22 Sep 1965

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5310-00-792-4797 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
R407P1B1 - Source of Control Reference2 - Production ItemGENERAL ELECTRIC COMPANY  07482    CAGE 07482  
LHTA517-2860-023 - Design Control Reference2 - Production ItemMACLEAN-FOGG COMPANY  019L2    CAGE 019L2  
LHTA517-2860-025 - Replaced / Discontinued9 - No Longer UsedHARVARD INDUSTRIES INC  72962    CAGE 72962  
Code Definitions

1 - Source of Control Reference

Reference Number Category Code (DRN_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5310-00-792-4797 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
535310007924797A021A005280X43ANS09 Aug 1968
Code Definitions

53

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Hardware and Abrasives

5310

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Nuts and Washers

007924797

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5310-00-792-4797

A021A0

Federal Item Identification Guide (FIIG_4065)

05280

Item Naming Code (INC_4080)

9 Aug 1968

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5310-00-792-4797 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Apr 1991
ZB011 Sep 2000
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5310-00-792-4797 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3122SEDR407P1B  07482   CAGE/07482
325ZZLHTA517-2860-02  019L2   CAGE/019L2
3595SEBLHTA517-2860-02  72962   CAGE/72962
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

1

Reference Number Category Code (RNCC_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

SE

Reference Number Action Activity Code (RNAAC_2900)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5310-00-792-4797 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3KZ11KZ022 Sep 1965 5310007793601 9 Jun 1971
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

KZ

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

22 Sep 1965

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5310-00-779-3601

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

9 Jun 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5310-00-792-4797 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SGQ576ZZABZQ013540X05680ALUM-NUTS
Code Definitions

SG

Originating Activity Code (ORIG_ACTY_CD_4210)


403 SCMS/GUED, 5215 Thurlow St, Suite 5, Bldg 70C Wright-Patterson AFB OH 45433

Q

Less Than Carload (LCL_CD_2760)


70

576

Water Commodity Code (WRT_CMDTY_CD_9275)


Metal and Metal Products, (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

Z

Special Handling Code (SP_HDLG_CD_9240)


No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

013540

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

05680

Uniform Freight Classification (UFC_CD_MODF_3040)

ALUM-NUTS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5310-00-792-4797 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9IYU5EA0
Code Definitions

S9I

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Troop Support, Philadelphia, PA 19111 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

5

Quantity Unit Pack (QUP_6106)


5

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5310-00-792-4797 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADFYCenter To Center Distance Between Mounting Holes Along Length0.310 INCHES MINIMUM AND 0.314 INCHES MAXIMUM
ADFWDistance From Aperture Center To Mounting Hole Center0.339 INCHES MINIMUM AND 0.349 INCHES MAXIMUM
CBBLFeatures ProvidedFLOATING NUT
MATTMaterialSTEEL OVERALL
ADFUMounting Hole Arrangement Style2 HOLES
ABTBMounting Hole Diameter0.098 INCHES MINIMUM AND 0.103 INCHES MAXIMUM
CQJXNominal Thread Size0.190 INCHES
ADEANut Height0.215 INCHES MAXIMUM
ACVNNut Length1.051 INCHES MAXIMUM
ADFPNut Mounting ProvisionSTRAIGHT HOLES
ACTANut StylePLATE
AAUMLocking FeaturePREVAILING TORQUE ALL METAL DESIGN
MDCLMaterial Document And ClassificationA286,ELASTIC STOP NUT CORP OF AMERICA MFR REF SINGLE MATERIAL RESPONSE OVERALL
ADECPlate Width0.416 INCHES MAXIMUM
ADEBPlate Thickness0.025 INCHES NOMINAL
PRMTPrecious MaterialSILVER
STDCSurface Treatment Document And ClassificationAMS 2410 ASSN STD SINGLE TREATMENT RESPONSE OVERALL
SFTTSurface TreatmentSILVER OVERALL
AZKQTemp Rating900.0 DEG FAHRENHEIT NOMINAL
AAJDThread Class3B
AAJFThread DirectionRIGHT-HAND
BZRRThread SeriesUNJF
CMLPThread Quantity Per Inch32


Back to Top