5310-00-849-9914

NUT,SELF-LOCKING,PLATE


5310-00-849-9914 (5310008499914, 008499914)
Part Numbers (12 listings): LHA27M2860-62 | MF6331-06 | 33C814-004 | 7117505-2 | 10105989-2 | 307302-2 | 203-6031P002 | 16610173-001 | 11108-002 | 634504-2 | 2130194G002 | FD-N0001-002 |
Summary

FSG 53 / FSC 5310

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

Unit Weight: 0.1 lbs

Unit Size: None

Unit Pack Cube: 0.007 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5310-00-849-9914 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
LHA27M2860-623 - Design Control Reference2 - Production ItemSPS TECHNOLOGIES, LLC  80539    CAGE 80539  
MF6331-065 - Replaced / Discontinued2 - Production ItemSATAIR A/S  R1120    CAGE R1120  
LHA27M2860-625 - Replaced / Discontinued9 - No Longer UsedHARVARD INDUSTRIES INC  72962    CAGE 72962  
33C814-0045 - Replaced / Discontinued9 - No Longer UsedAIL SYSTEMS INC  04660    CAGE 04660  
7117505-25 - Replaced / Discontinued9 - No Longer UsedLITTON SYSTEMS INC  17863    CAGE 17863  
10105989-25 - Replaced / Discontinued9 - No Longer UsedU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
307302-25 - Replaced / Discontinued9 - No Longer UsedNORTHROP GRUMMAN SYSTEMS CORPORATION  15280    CAGE 15280  
203-6031P0025 - Replaced / Discontinued9 - No Longer UsedRAYTHEON TECHNICAL SERVICES COMPANY  3B150    CAGE 3B150  
16610173-0015 - Replaced / Discontinued9 - No Longer UsedSYPRIS ELECTRONICS, LLC  28009    CAGE 28009  
11108-0025 - Replaced / Discontinued9 - No Longer UsedASTRONAUTICS CORPORATION OF AMERICA  10138    CAGE 10138  
MF6331-065 - Replaced / Discontinued9 - No Longer UsedALCOA GLOBAL FASTENERS, INC.  15653      
203-6031P0025 - Replaced / Discontinued9 - No Longer UsedRAYTHEON COMPANY  49956    CAGE 49956  
634504-25 - Replaced / Discontinued9 - No Longer UsedRAYTHEON COMPANY  96214    CAGE 96214  
2130194G0027 - Vendor Item Drawing Reference2 - Production ItemEXELIS INC.  28527    CAGE 28527  
LHA27M2860-62C - Advisory Reference1 - Incomplete Part NumberMACLEAN-FOGG COMPANY  019L2    CAGE 019L2  
LHA27M2860-62C - Advisory Reference1 - Incomplete Part NumberMACLEAN-FOGG COMPANY  019L2    CAGE 019L2  
LHA27M2860-62C - Advisory Reference1 - Incomplete Part NumberAMERACE LTD  13257      
FD-N0001-002C - Advisory Reference1 - Incomplete Part NumberRAYTHEON E-SYSTEMS INC  33875    CAGE 33875  
7117505-2C - Advisory Reference1 - Incomplete Part NumberNORTHROP GRUMMAN GUIDANCE AND  06481    CAGE 06481  
7117505-2C - Advisory Reference1 - Incomplete Part NumberNORTHROP GRUMMAN GUIDANCE AND  06481    CAGE 06481  
307302-2C - Advisory Reference1 - Incomplete Part NumberNORTHROP GRUMMAN SYSTEMS CORPORATION  26916    CAGE 26916  
307302-2C - Advisory Reference1 - Incomplete Part NumberNORTHROP GRUMMAN SYSTEMS CORPORATION  26916    CAGE 26916  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5310-00-849-9914 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
535310008499914A021A005280X1ANS1 Jan 1963
Code Definitions

53

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Hardware and Abrasives

5310

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Nuts and Washers

008499914

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5310-00-849-9914

A021A0

Federal Item Identification Guide (FIIG_4065)

05280

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 5310-00-849-9914 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
YD011 Apr 1991
YJ011 Apr 1991
ZA011 Apr 1991
ZC011 Apr 1991
ZE011 Apr 1991
ZF011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
ZP011 Apr 1991
ZR011 Apr 1991
ZS011 Apr 1991
ZT011 Apr 1991
ZU011 Aug 1995
ZW011 Nov 1998
YA011 Oct 2000
ZX011 Sep 2004
A919A1871CZCDBDCLBF1 Apr 2006
FXGIFXKZ1CZSXSJ1 Apr 2006
N9BZN9ZD1CZGHGTKEJBHX1 Apr 2006
WP011 Nov 2006
ZB011 Nov 2006
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

C

Acquisition Method Suffix Code (AMSC_2876)


This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

CD

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army War Reserve Command, New Cumberland, PA 17070-5008

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111

JBCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Mechanicsburg, PA 17055-0788

HXCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Navy ICP, Mechanicsburg, PA 17055-0788

BD

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

CL

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

BF

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000

SJ

Supplementary Receivers (SUPPLM_RCVR_2534)


Air Force Cryptological Support Center, San Antonio, TX 78243-5000


FLIS - SEG C - REFERENCE NUMBER | NSN 5310-00-849-9914 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZLHA27M2860-62  80539   CAGE/80539
4526ZGDMF6331-06  R1120   CAGE/R1120
3595KEB634504-2  96214   CAGE/96214
45919ZB16610173-001  28009   CAGE/28009
591KZB203-6031P002  3B150   CAGE/3B150
59AKZB203-6031P002  49956   CAGE/49956
3595KEB33C814-004  04660   CAGE/04660
45929ZB11108-002  10138   CAGE/10138
596KZB307302-2  15280   CAGE/15280
45959ZBMF6331-06  15653  
595KEB7117505-2  17863   CAGE/17863
3591BDB10105989-2  18876   CAGE/18876
722KZ2130194G002  28527   CAGE/28527
C19TUABFD-N0001-002  33875   CAGE/33875
C15ZZ9FLHA27M2860-62  019L2   CAGE/019L2
C15ZZ9F307302-2  26916   CAGE/26916
C15ZZACLHA27M2860-62  13257  
C15ZZ9F7117505-2  06481   CAGE/06481
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZG

Reference Number Action Activity Code (RNAAC_2900)


Germany

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

KE

Reference Number Action Activity Code (RNAAC_2900)


Naval ICP, Philadelphia, PA 19111

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

KZ

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

BD

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9

Document Availability Code (DAC_2640)


The reference number is of the type for which an indication of document availability is not required.

TU

Reference Number Action Activity Code (RNAAC_2900)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

AB

Service / Agency Designator Code (SADC_4672)


Air Force

9F

Service / Agency Designator Code (SADC_4672)


CAGE Status Change

AC

Service / Agency Designator Code (SADC_4672)


Navy


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5310-00-849-9914 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2KZ022 Sep 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KZ

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

22 Sep 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5310-00-849-9914 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
573Z9ABZW093486Z48950BOLTS-NUTS-OR-SCREWS--NOI--SUB-3-
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


573

Water Commodity Code (WRT_CMDTY_CD_9275)


Bolts or Nuts (Iron or Steel), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

093486

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

48950

Uniform Freight Classification (UFC_CD_MODF_3040)

BOLTS-NUTS-OR-SCREWS--NOI--SUB-3-

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5310-00-849-9914 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSZUQAEA0
DFSMSZUQNEA0
DNSMSZUQEA0
DSSMSZUQNEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

Q

Quantity Unit Pack (QUP_6106)


100

A

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions. NAVY: Field Activity Control Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5310-00-849-9914 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP101AAA0.1 lbs0.007 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00000001000EO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

10

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Physical protection

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.1 lbs

Unit Pack Weight (UP_WT_5153)

0.007 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

10

Unit Container Code (UNIT_CTNR_CD_5166)


Any suitable container included in this table may be used (see J.4.9.1).

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

E

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5310-00-849-9914 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADBRDistance From Base To Center Of Aperture0.141 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
ADFVDistance From Mounting Hole Center To Base0.215 INCHES MINIMUM AND 0.245 INCHES MAXIMUM
ADFYCenter To Center Distance Between Mounting Holes Along Length0.138 INCHES MINIMUM AND 0.142 INCHES MAXIMUM
CBBLFeatures ProvidedFLOATING NUT
MATTMaterialIRON ALLOY 660 OVERALL
ADFUMounting Hole Arrangement Style2 HOLES
ABTBMounting Hole Diameter0.066 NOMINAL MILS AND 0.069 NOMINAL CENTIMETERS
CQJXNominal Thread Size0.138 INCHES
ACVNNut Length0.440 INCHES MINIMUM AND 0.470 INCHES MAXIMUM
ADEANut Height0.132 NOMINAL MILS AND 0.162 NOMINAL CENTIMETERS
ADFPNut Mounting ProvisionSTRAIGHT HOLES
ACTANut StylePLATE
AAUMLocking FeaturePREVAILING TORQUE ALL METAL DESIGN
ABAJLubricationDRY FILM LUBRICANT
MDCLMaterial Document And ClassificationAMS 5735 ASSN STD SINGLE MATERIAL RESPONSE OVERALL
ADEBPlate Thickness0.010 NOMINAL MILS AND 0.040 NOMINAL CENTIMETERS
ADECPlate Width0.251 INCHES MINIMUM AND 0.281 INCHES MAXIMUM
PRMTPrecious MaterialSILVER
STDCSurface Treatment Document And ClassificationAMS 2410 ASSN STD SINGLE TREATMENT RESPONSE NUT
SFTTSurface TreatmentSILVER NUT
AZKQTemp Rating900.0 DEG FAHRENHEIT NOMINAL
AAJDThread Class3B
AAJFThread DirectionRIGHT-HAND
BZRRThread SeriesUNC
CMLPThread Quantity Per Inch32


Back to Top