5310-01-219-4168

NUT,SELF-LOCKING,PLATE


5310-01-219-4168 (5310012194168, 012194168)
Part Numbers (3 listings): GN500J08A | NS103884-82 | T12S832K1 |
Summary

FSG 53 / FSC 5310

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 26 Oct 1985

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5310-01-219-4168 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
GN500J08A3 - Design Control Reference2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  26512    CAGE 26512  
NS103884-825 - Replaced / Discontinued2 - Production ItemSPS TECHNOLOGIES, LLC  80539    CAGE 80539  
T12S832K15 - Replaced / Discontinued9 - No Longer UsedSPS TECHNOLOGIES, LLC  11815    CAGE 11815  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5310-01-219-4168 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
535310012194168A021A005280X43ANAA026 Oct 1985
Code Definitions

53

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Hardware and Abrasives

5310

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Nuts and Washers

012194168

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5310-01-219-4168

A021A0

Federal Item Identification Guide (FIIG_4065)

05280

Item Naming Code (INC_4080)

26 Oct 1985

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5310-01-219-4168 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZZ
N9BZ00ZKEHX1 Mar 2014
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

KE

Item Management Coding Activity (IMC_ACTY_2748)


Naval ICP, Philadelphia, PA 19111

HXCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Navy ICP, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5310-01-219-4168 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32AZZGN500J08A  26512   CAGE/26512
52AZZNS103884-82  80539   CAGE/80539
595ZZBT12S832K1  11815   CAGE/11815
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG G - FREIGHT DATA | NSN 5310-01-219-4168 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
GX713Z9ABZW093486Z48950BOLTS-NUTS-OR-SCREWS--NOI--SUB-3-
Code Definitions

GX

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ Defense Logistics Agency, Enterprise Business, Systems, Fort Belvoir, VA 22060

713

Water Commodity Code (WRT_CMDTY_CD_9275)


Metal Hardware

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

093486

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

48950

Uniform Freight Classification (UFC_CD_MODF_3040)

BOLTS-NUTS-OR-SCREWS--NOI--SUB-3-

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5310-01-219-4168 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSJU0EA0
DSSMSJU0EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5310-01-219-4168 Submit RFQ
MRCDecoded RequirementClear Text Reply
BZRRThread SeriesUNJC
CQJXNominal Thread Size0.164 INCHES
CMLPThread Quantity Per Inch32
AAJDThread Class3B
AAJFThread DirectionRIGHT-HAND
MATTMaterialSTEEL OVERALL
SFTTSurface TreatmentCADMIUM AND
SFTTSurface TreatmentCHROMATE OVERALL
STDCSurface Treatment Document And ClassificationQQ-P-416,TY 2,CL 2 FED SPEC SINGLE TREATMENT RESPONSE OVERALL
CQFMHardness Rating36.0 ROCKWELL C MINIMUM
ACTANut StylePLATE
ACVNNut Length0.935 INCHES MAXIMUM
ADEANut Height0.365 INCHES MINIMUM AND
ADEANut Height0.395 INCHES MAXIMUM
ADEBPlate Thickness0.040 INCHES MAXIMUM
ADECPlate Width0.297 INCHES MAXIMUM
AAUMLocking FeaturePREVAILING TORQUE ALL METAL DESIGN
ADFKNut Counterbore Depth0.062 INCHES NOMINAL NUT
AAWYCounterbore Diameter0.168 INCHES MINIMUM NUT
ABAJLubricationSOLUBLE LUBRICANT
ADFPNut Mounting ProvisionSTRAIGHT HOLES
ADFUMounting Hole Arrangement Style2 HOLES
ABTBMounting Hole Diameter0.098 INCHES MINIMUM AND
ABTBMounting Hole Diameter0.103 INCHES MAXIMUM
ADFWDistance From Aperture Center To Mounting Hole Center0.339 INCHES MINIMUM AND
ADFWDistance From Aperture Center To Mounting Hole Center0.349 INCHES MAXIMUM
ADFYCenter To Center Distance Between Mounting Holes Along Length0.310 INCHES MINIMUM AND
ADFYCenter To Center Distance Between Mounting Holes Along Length0.314 INCHES MAXIMUM
AZKQTemp Rating450.0 DEG FAHRENHEIT MAXIMUM


Back to Top
Back to Top