5315-01-041-1433

PIN,SPRING


5315-01-041-1433 (5315010411433, 010411433)
Part Number (1 listing): NAS1407C10M7
Summary

FSG 53 / FSC 5315

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 20 May 1977

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5315-01-041-1433 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
NAS1407C10M73 - Design Control Reference2 - Production ItemNATIONAL AEROSPACE STANDARDS  80205    CAGE 80205  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5315-01-041-1433 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
535315010411433A212A002389X1ANA20 May 1977
Code Definitions

53

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Hardware and Abrasives

5315

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Nails, Machine Keys, and Pins

010411433

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5315-01-041-1433

A212A0

Federal Item Identification Guide (FIIG_4065)

02389

Item Naming Code (INC_4080)

20 May 1977

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5315-01-041-1433 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YS011 Feb 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5315-01-041-1433 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
13249ZDNAS1407C10M7  80205   CAGE/80205
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5315-01-041-1433 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2KZ64 Dec 1983
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KZ

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

4 Dec 1983

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5315-01-041-1433 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
9ZQ713ZZAAZQ095190J49790HARDWARE--NOI-SUB-9
Code Definitions

9Z

Originating Activity Code (ORIG_ACTY_CD_4210)


DLIS-K, Battle Creek, MI 49037-3084

Q

Less Than Carload (LCL_CD_2760)


70

713

Water Commodity Code (WRT_CMDTY_CD_9275)


Metal Hardware

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

Z

Special Handling Code (SP_HDLG_CD_9240)


No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

A

Air Commodity Code (AIR_CMTY_HDLG_9215)


Supplies and equipment for aircraft and aerial targets, including aircraft and maintenance parts, aircraft accessories, aircraft instruments and laboratory test equipment, aerial targets and gliders, aircraft/missile technical order compliance kits, etc

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

095190

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

J

NMFC Sub Item Number (SUB_ITM_NBR_0861)

49790

Uniform Freight Classification (UFC_CD_MODF_3040)

HARDWARE--NOI-SUB-9

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5315-01-041-1433 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABMZDiameter0.156 INCHES NOMINAL
ABPYExpanded Diameter0.163 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
MATTMaterialSTEEL COMP 420 OVERALL
MDCLMaterial Document And ClassificationAISI ASSN STD SINGLE MATERIAL RESPONSE OVERALL
CQSXShear Strength1925 DOUBLE POUNDS PER SQUARE INCH
ABHPOverall Length0.438 INCHES NOMINAL
ZZZKSpecification/Standard Data80205-NAS1407 PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD
STYLStyle DesignatorCOILED
STDCSurface Treatment Document And ClassificationQQ-P-35 FED SPEC SINGLE TREATMENT RESPONSE OVERALL
SFTTSurface TreatmentPASSIVATE OVERALL


Back to Top