5315-01-154-9199

PIN,QUICK RELEASE


5315-01-154-9199 (5315011549199, 011549199)
Part Number (1 listing): NAS1335A6S06D
Summary

FSG 53 / FSC 5315

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 2 Jun 1983

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5315-01-154-9199 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
NAS1335A6S06D3 - Design Control Reference2 - Production ItemNATIONAL AEROSPACE STANDARDS  80205    CAGE 80205  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5315-01-154-9199 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
535315011549199A212A008323X1ANU2 Jun 1983
Code Definitions

53

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Hardware and Abrasives

5315

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Nails, Machine Keys, and Pins

011549199

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5315-01-154-9199

A212A0

Federal Item Identification Guide (FIIG_4065)

08323

Item Naming Code (INC_4080)

2 Jun 1983

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5315-01-154-9199 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZS011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5315-01-154-9199 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDNAS1335A6S06D  80205   CAGE/80205
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5315-01-154-9199 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59702 Jun 1983
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

2 Jun 1983

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5315-01-154-9199 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZSQ713Z9ABZQ095190J49790HARDWARE--NOI-SUB-9
Code Definitions

ZS

Originating Activity Code (ORIG_ACTY_CD_4210)


Denmark

Q

Less Than Carload (LCL_CD_2760)


70

713

Water Commodity Code (WRT_CMDTY_CD_9275)


Metal Hardware

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

095190

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

J

NMFC Sub Item Number (SUB_ITM_NBR_0861)

49790

Uniform Freight Classification (UFC_CD_MODF_3040)

HARDWARE--NOI-SUB-9

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5315-01-154-9199 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFLWActuation MethodPUSH BUTTON
APCMActuation TypePUSH
ABRMDetent Quantity2
CTXTDetent To Tapered End Distance0.400 INCHES MAXIMUM
ANEEGrip Length0.600 INCHES MINIMUM AND 0.620 INCHES MAXIMUM
MATTMaterialALUMINUM HEAD
MATTMaterialSTEEL CORROSION RESISTING DETENT
MATTMaterialSTEEL SHANK
AAZEShank Diameter0.3095 INCHES MINIMUM AND 0.3120 INCHES MAXIMUM
CRQDShoulder To Head End Distance1.547 INCHES MAXIMUM
CTDJPin Attachment TypeRING OR HOOK
CSSBPin Center To Handle End Distance1.781 INCHES MAXIMUM
STYLStyle DesignatorL HANDLE
STDCSurface Treatment Document And ClassificationMIL-C-5541 MIL SPEC SINGLE TREATMENT RESPONSE HEAD
STDCSurface Treatment Document And ClassificationQQ-P-416,TYPE 2,CLASS 2 FED SPEC SINGLE TREATMENT RESPONSE SHANK
SFTTSurface TreatmentCADMIUM SHANK
SFTTSurface TreatmentOXIDE FILM HEAD
SFTTSurface TreatmentPASSIVATE DETENT


Back to Top