5315-01-197-8213

PIN,SHOULDER,HEADLESS


5315-01-197-8213 (5315011978213, 011978213)
Part Numbers (6 listings): VCW0054-4 | PBF1406-4 | 123486-4 | 3M1093-4 | 74A501252-2007 | 10123210 |
Summary

FSG 53 / FSC 5315

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 29 Dec 1984

Unit Weight: 0.1 lbs

Unit Size: None

Unit Pack Cube: 0.001 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5315-01-197-8213 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
VCW0054-43 - Design Control Reference2 - Production ItemVALLEY-TODECO, INC.  06710    CAGE 06710  
PBF1406-43 - Design Control Reference2 - Production ItemSPS TECHNOLOGIES, LLC  27624    CAGE 27624  
123486-43 - Design Control Reference2 - Production ItemSPS TECHNOLOGIES, LLC  80539    CAGE 80539  
3M1093-45 - Replaced / Discontinued2 - Production ItemBOEING COMPANY, THE  76301    CAGE 76301  
3M1093-45 - Replaced / Discontinued2 - Production ItemTHOMAS INSTRUMENT, INCORPORATED  5H860      
74A501252-20075 - Replaced / Discontinued9 - No Longer UsedBOEING COMPANY, THE  76301    CAGE 76301  
101232106 - Informative Reference9 - No Longer UsedPAEAEESIKUNTA  A486G      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

6 - Informative Reference

Reference Number Category Code (DRN_2910)


Informative Reference. North Atlantic Treaty Organization (NATO) Stock Numbers (CAGE Code 99995), Production Equipment Codes (CAGE 99998), and DoD Ammunition Codes (CAGE Code 99999) which may be related to NSNs. (Reference numbers for the CAGE Codes cited above shall be coded RNVC 9.)

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5315-01-197-8213 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
535315011978213A212A016749X1ANA029 Dec 1984
Code Definitions

53

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Hardware and Abrasives

5315

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Nails, Machine Keys, and Pins

011978213

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5315-01-197-8213

A212A0

Federal Item Identification Guide (FIIG_4065)

16749

Item Naming Code (INC_4080)

29 Dec 1984

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5315-01-197-8213 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZA011 Apr 1991
ZC011 Apr 1991
YW011 Aug 1997
N9BZN9ZD1CZKEGTKE1 Aug 2005
WF011 Aug 2009
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

C

Acquisition Method Suffix Code (AMSC_2876)


This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

KE

Item Management Coding Activity (IMC_ACTY_2748)


Naval ICP, Philadelphia, PA 19111

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG C - REFERENCE NUMBER | NSN 5315-01-197-8213 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32AKZVCW0054-4  06710   CAGE/06710
32AKZPBF1406-4  27624   CAGE/27624
32AKZ123486-4  80539   CAGE/80539
52AZZ3M1093-4  5H860  
52AKZ3M1093-4  76301   CAGE/76301
59AKZB74A501252-2007  76301   CAGE/76301
4699WFB10123210  A486G  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

KZ

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

6

Reference Number Category Code (RNCC_2910)


Informative Reference. North Atlantic Treaty Organization (NATO) Stock Numbers (CAGE Code 99995), Production Equipment Codes (CAGE 99998), and DoD Ammunition Codes (CAGE Code 99999) which may be related to NSNs. (Reference numbers for the CAGE Codes cited above shall be coded RNVC 9.)

9

Document Availability Code (DAC_2640)


The reference number is of the type for which an indication of document availability is not required.

WF

Reference Number Action Activity Code (RNAAC_2900)


Finland


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5315-01-197-8213 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6KZ030 Dec 1984
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

KZ

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

30 Dec 1984

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5315-01-197-8213 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KZ713Z9ABZQ095190J49790HARDWARE--NOI-SUB-9
Code Definitions

KZ

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

713

Water Commodity Code (WRT_CMDTY_CD_9275)


Metal Hardware

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

Q

Less Than Truckload (CLAS_RTNG_CD_2770)


70

095190

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

J

NMFC Sub Item Number (SUB_ITM_NBR_0861)

49790

Uniform Freight Classification (UFC_CD_MODF_3040)

HARDWARE--NOI-SUB-9

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5315-01-197-8213 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSZU1EA0
DSSMSZU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5315-01-197-8213 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP1010000.1 lbs0.001 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XD30000EQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

10

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Physical protection

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.1 lbs

Unit Pack Weight (UP_WT_5153)

0.001 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

E

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5315-01-197-8213 Submit RFQ
MRCDecoded RequirementClear Text Reply
CRDYFirst End LocationTHREADED END
AAGZFirst End StyleCHAMFERED
CRMGFirst End Taper Angle44.5 DEGREES MINIMUM AND 45.5 DEGREES MAXIMUM
AMCSFirst End Taper Length0.060 INCHES MINIMUM AND 0.070 INCHES MAXIMUM
ABPRFirst Step Diameter0.8273 INCHES MINIMUM AND 0.8278 INCHES MAXIMUM
ABPSFirst Step Length1.330 INCHES NOMINAL
MATTMaterialSTEEL COMP XM-13 OVERALL
CQJXNominal Thread Size0.500 INCHES
ABQZInternal Drive StyleSOCKET
MDCLMaterial Document And ClassificationAMS 5629 ASSN STD SINGLE MATERIAL RESPONSE OVERALL
AKVASecond End Counterbore Depth0.098 INCHES NOMINAL
AAHPSecond End StyleCOUNTERBORED W/O THRU HOLE
CQBBSecond End Relationship With First EndNOT IDENTICAL
ABPTSecond Step Diameter0.5990 INCHES MINIMUM AND 0.5994 INCHES MAXIMUM
ABPUSecond Step Length1.000 INCHES NOMINAL
FEATSpecial FeaturesDRY FILM LUBRICANT
AAULWidth Between Flats0.375 INCHES MINIMUM AND 0.379 INCHES MAXIMUM
STYLStyle DesignatorSHOULDER
CSYMSurface Finish32.0 MICROINCHES OVERALL
ABPVThird Step Diameter0.500 INCHES NOMINAL
ABPWThird Step Length0.900 INCHES NOMINAL
AAJDThread Class3A
AAJFThread DirectionRIGHT-HAND
AASAThread Length0.835 INCHES NOMINAL
THSDThread Series DesignatorUNJF
CMLPThread Quantity Per Inch20


Back to Top
Back to Top