Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
11019318-1 | 3 - Design Control Reference | 2 - Production Item | NORTHROP GRUMMAN GUIDANCE AND | 34860 | ![]() |
CA1826-1 | 3 - Design Control Reference | 2 - Production Item | ALCOA GLOBAL FASTENERS, INC. | 29372 | ![]() |
10224820 | 3 - Design Control Reference | 2 - Production Item | U S ARMY AVIATION AND MISSILE | 18876 | ![]() |
2887834-1 | 5 - Replaced / Discontinued | 2 - Production Item | RAYTHEON TECHNICAL SERVICES COMPANY | 3B150 | ![]() |
740139-01 | 5 - Replaced / Discontinued | 2 - Production Item | GE AVIATION SYSTEMS LLC | 35351 | ![]() |
2887834-1 | 5 - Replaced / Discontinued | 2 - Production Item | RAYTHEON COMPANY | 54X10 | ![]() |
GR540AA1 | 5 - Replaced / Discontinued | 2 - Production Item | APPLIED INDUSTRIAL TECHNOLOGIES -- | 76512 | ![]() |
HS4497-1 | 5 - Replaced / Discontinued | 2 - Production Item | JORDAN PRODUCTS | 0NEM2 | ![]() |
CA1826-1 | 5 - Replaced / Discontinued | 2 - Production Item | ALCOA FASTENING SYSTEMS | D0680 | ![]() |
423315-1 | 5 - Replaced / Discontinued | 2 - Production Item | NAVAL AIR WARFARE CENTER AIRCRAFT | 80020 | ![]() |
29906.0M0 | 5 - Replaced / Discontinued | 2 - Production Item | BENNING ELEKTROTECHNIK UNDELEKTRONIK | D0623 | ![]() |
911537-3 | 5 - Replaced / Discontinued | 2 - Production Item | NORTHROP GRUMMAN GUIDANCE AND | 06481 | ![]() |
GR540AA1 | 5 - Replaced / Discontinued | 2 - Production Item | NORTHROP GRUMMAN SYSTEMS CORPORATION | 26512 | ![]() |
719601-1 | 5 - Replaced / Discontinued | 2 - Production Item | RAYTHEON COMPANY | 05869 | ![]() |
3013824-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | NAVAIR AND NAVSEA MANAGED | 10001 | ![]() |
2887834-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | NAVAIR AND NAVSEA MANAGED | 10001 | ![]() |
1716-001 | 5 - Replaced / Discontinued | 9 - No Longer Used | UNIVERSITY OF MICHIGAN | 71780 | ![]() |
5365007581034 | 5 - Replaced / Discontinued | 9 - No Longer Used | E.C.A ETABLISSEMENT | SCY13 | ![]() |
2887834-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 49956 | ![]() |
K3650008-7 | 5 - Replaced / Discontinued | 9 - No Longer Used | MCDONNELL DOUGLAS CORP | 12464 | ![]() |
HS4497-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | MCDONNELL DOUGLAS HELICOPTER CO INC | 02731 | ![]() |
100718670-102 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTERNATIONAL INC. | 94580 | ![]() |
10071867-102 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTERNATIONAL INC. | 94580 | ![]() |
10198526 | 6 - Informative Reference | 9 - No Longer Used | PAEAEESIKUNTA | A486G | ![]() |
805234-1 | 7 - Vendor Item Drawing Reference | 2 - Production Item | RAYTHEON COMPANY | 96214 | ![]() |
717801716-001 | 7 - Vendor Item Drawing Reference | 2 - Production Item | LOCKHEED MARTIN CORPORATION | 04939 | ![]() |
HS4497-1 | 7 - Vendor Item Drawing Reference | 2 - Production Item | BOEING COMPANY, THE | 8V613 | ![]() |
963429-1 | 7 - Vendor Item Drawing Reference | 2 - Production Item | RAYTHEON COMPANY | 82577 | ![]() |
615396-6 | C - Advisory Reference | 1 - Incomplete Part Number | NAVAL AIR WARFARE CENTER AIRCRAFT | 80020 | ![]() |
CA1826-1 | C - Advisory Reference | 1 - Incomplete Part Number | TYCO ELECTRONICS CORP | 26805 | ![]() |
615396-6 | C - Advisory Reference | 1 - Incomplete Part Number | BOSCH REXROTH GMBH LOHMANN | D9182 | ![]() |
5223430-3 | C - Advisory Reference | 1 - Incomplete Part Number | BOSCH REXROTH GMBH LOHMANN | D9182 | ![]() |
5019102 | C - Advisory Reference | 1 - Incomplete Part Number | BOSCH REXROTH GMBH LOHMANN | D9182 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Informative Reference. North Atlantic Treaty Organization (NATO) Stock Numbers (CAGE Code 99995), Production Equipment Codes (CAGE 99998), and DoD Ammunition Codes (CAGE Code 99999) which may be related to NSNs. (Reference numbers for the CAGE Codes cited above shall be coded RNVC 9.)
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
53 | 5325 | 007581034 | T252-G | 07623 | X | 4 | 3 | A | N | A | 0 | 1 Jan 1960 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YD01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZE01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZK01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZN01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZS01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZT01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZX01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Feb 1994 | |||||||||||||||||||||||||||||
ZU01 | 1 Aug 1995 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
YA01 | 1 Sep 2000 | |||||||||||||||||||||||||||||
WB01 | 1 Feb 2005 | |||||||||||||||||||||||||||||
WP01 | 1 Jul 2005 | |||||||||||||||||||||||||||||
A919 | A187 | 1 | C | Z | CD | AZ | CT | CL | BD | 1 Apr 2006 | ||||||||||||||||||||
FXGI | FXKZ | 1 | C | Z | SX | 1 Apr 2006 | ||||||||||||||||||||||||
MC47 | MC10 | 1 | C | Z | PA | 1 Apr 2006 | ||||||||||||||||||||||||
N9BZ | N9ZD | 1 | C | Z | GH | GT | KE | JV | JB | HX | HS | HD | 1 Apr 2006 | |||||||||||||||||
YP01 | 1 Nov 2008 | |||||||||||||||||||||||||||||
ZD01 | 1 Oct 2009 | |||||||||||||||||||||||||||||
WF01 | 1 Dec 2009 | |||||||||||||||||||||||||||||
YK01 | 1 Feb 2015 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
Strategic Systems Programs C/O Tracor Sys Engineering Rockville, MD 20850-1160
Naval ICP, Mechanicsburg, PA 17055-0788
Navy ICP, Mechanicsburg, PA 17055-0788
HD
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
U.S. Army Tank-Automotive and Armaments, Command, Warren, MI 48397-5000
U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 1 | BD | D | 10224820 | 18876 | ![]() | ||||
3 | 3 | 2 | 5 | KZ | D | CA1826-1 | 29372 | ![]() | ||||
4 | 3 | 2 | 1 | KZ | D | 11019318-1 | 34860 | ![]() | ||||
3 | 5 | 2 | 5 | KE | D | 740139-01 | 35351 | ![]() | ||||
5 | 2 | 4 | 9Z | 2887834-1 | 3B150 | ![]() | ||||||
4 | 5 | 2 | 1 | KE | B | GR540AA1 | 76512 | ![]() | ||||
5 | 2 | 1 | KE | 423315-1 | 80020 | ![]() | ||||||
4 | 5 | 2 | 1 | KZ | D | GR540AA1 | 26512 | ![]() | ||||
5 | 2 | A | ZZ | 719601-1 | 05869 | ![]() | ||||||
3 | 5 | 2 | 5 | CL | D | 911537-3 | 06481 | ![]() | ||||
5 | 2 | E | ZZ | HS4497-1 | 0NEM2 | ![]() | ||||||
4 | 5 | 2 | 1 | ZG | A | 29906.0M0 | D0623 | ![]() | ||||
4 | 5 | 2 | 3 | ZG | A | CA1826-1 | D0680 | ![]() | ||||
5 | 2 | 5 | ZZ | 2887834-1 | 54X10 | ![]() | ||||||
5 | 9 | 1 | BF | 10071867-102 | 94580 | ![]() | ||||||
5 | 9 | 1 | BF | 100718670-102 | 94580 | ![]() | ||||||
4 | 5 | 9 | 9 | YP | B | 5365007581034 | SCY13 | ![]() | ||||
4 | 5 | 9 | 4 | 9Z | B | 2887834-1 | 10001 | ![]() | ||||
5 | 9 | 5 | ZZ | B | 3013824-1 | 10001 | ![]() | |||||
5 | 9 | 1 | KZ | B | K3650008-7 | 12464 | ![]() | |||||
5 | 9 | 5 | ZZ | B | HS4497-1 | 02731 | ![]() | |||||
4 | 5 | 9 | 4 | 9Z | B | 2887834-1 | 49956 | ![]() | ||||
5 | 9 | 5 | KZ | B | 1716-001 | 71780 | ![]() | |||||
4 | 6 | 9 | 9 | WF | B | 10198526 | A486G | ![]() | ||||
7 | 2 | 1 | KE | 805234-1 | 96214 | ![]() | ||||||
7 | 2 | 1 | KE | 963429-1 | 82577 | ![]() | ||||||
7 | 2 | 5 | 9Z | HS4497-1 | 8V613 | ![]() | ||||||
7 | 2 | B | KZ | 717801716-001 | 04939 | ![]() | ||||||
C | 1 | 5 | ZZ | AC | CA1826-1 | 26805 | ![]() | |||||
C | 1 | 5 | ZZ | AC | 615396-6 | 80020 | ![]() | |||||
C | 1 | 6 | ZZ | AC | 5019102 | D9182 | ![]() | |||||
C | 1 | 6 | ZZ | AC | 5223430-3 | D9182 | ![]() | |||||
C | 1 | 6 | ZZ | AC | 615396-6 | D9182 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Philadelphia, Philadelphia, PA 19101
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Naval ICP, Philadelphia, PA 19111
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
USA
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Germany
Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
The reference number is of the type for which an indication of document availability is not required.
Morocco
Informative Reference. North Atlantic Treaty Organization (NATO) Stock Numbers (CAGE Code 99995), Production Equipment Codes (CAGE 99998), and DoD Ammunition Codes (CAGE Code 99999) which may be related to NSNs. (Reference numbers for the CAGE Codes cited above shall be coded RNVC 9.)
Finland
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
The reference number is represented by an engineering drawing. The drawing is available for limited use under the terms of the rights-in-data clause of the contract by which the data was obtained and will be furnished by the activity identified by the RNAAC upon request. Descriptive data based on Limited Rights information will not be released to the general public through publications or other media.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
Navy
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | KZ | 0 | 25 May 1970 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Philadelphia, Philadelphia, PA 19101
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
713 | Z | 9 | A | B | Z | Q | 095190 | J | 49790 | HARDWARE--NOI-SUB-9 |
Metal Hardware
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
70
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | D | U | 1 | Z | PG | 0 | |
DF | SMS | D | U | 1 | N | PG | 0 | |
DM | SMS | D | U | 1 | Z | PG | 0 | |
DN | SMS | D | U | 1 | PG | 0 | ||
DS | SMS | D | U | 1 | N | PG | 0 |
Defense Logistics Agency, Enterprise Business Systems
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Package - A form of protective wrapping for two or more of the same item of supply. To be used only when a unit of measure or container type term is not applicable. Includes “envelope”. *Requires a quantitative expression
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | AAA | 0.1 lbs | 0.003 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | X | A1 | D3 | 00 | E | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
As required to protect the item or elements of the package
Bags made of material conforming to MIL-P-130, MIL-DTL-17667, MIL-PRF-121, or any material authorized by MIL-DTL-117. Closure may be by staples, tape, adhesive or heat seal.
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.