Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
4W21115-101A | 3 - Design Control Reference | 2 - Production Item | LOCKHEED MARTIN CORPORATION | 98897 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
53 | 5330 | 000039610 | A032A0 | 32847 | X | K | A | P | U | 27 May 1972 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FXGI | FXKZ | 1 | G | Z | SX | 1 Mar 2005 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | KZ | 0 | 27 Apr 1972 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Philadelphia, Philadelphia, PA 19101
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE | J | 596 | Z | Z | A | B | Z | C | 194120 | C | 95100 | WASHERS-GASKETS-PCKG-DVCS-NOI-SUB3 | 1 |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
100.2
Gaskets, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
250
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
No QUP
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
1
Department of the Air Force
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ABVL | Aperture Diameter | 20.620 INCHES NOMINAL |
CQCF | Construction | SOLID |
AARN | Fabrication Method | SOLID |
MATT | Material | RUBBER SYNTHETIC OVERALL |
MDCL | Material Document And Classification | MIL-R-6855 CL 2 GR 40 MIL SPEC SINGLE MATERIAL RESPONSE OVERALL |
STYL | Style Designator | CIRCULAR |