5330-00-488-3882

PACKING,PREFORMED


5330-00-488-3882 (5330004883882, 004883882)
Part Number (1 listing): MS17413-235
Summary

FSG 53 / FSC 5330

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 11 Jun 1969

Replacement NSN:

5331-00-165-1953

Replacement Date: 20 Sep 1974

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5330-00-488-3882 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
MS17413-2352 - Definitive Specification or Standard Document2 - Production ItemMILITARY STANDARDS  96906    CAGE 96906  
Code Definitions

2 - Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5330-00-488-3882 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
535330004883882A032A004521X1APU11 Jun 1969
Code Definitions

53

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Hardware and Abrasives

5330

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Packing and Gasket Materials

004883882

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5330-00-488-3882

A032A0

Federal Item Identification Guide (FIIG_4065)

04521

Item Naming Code (INC_4080)

11 Jun 1969

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5330-00-488-3882 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
ZS011 Apr 1991
ZW011 Sep 2009
ZG011 Jan 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5330-00-488-3882 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3224AZDMS17413-235  96906   CAGE/96906
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

2

Reference Number Category Code (RNCC_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

AZ

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Tank-Automotive and Armaments, Command, Warren, MI 48397-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5330-00-488-3882 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3KZ11KZ020 Sep 1974 5331001651953 14 Jan 0072
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

KZ

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

20 Sep 1974

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5331-00-165-1953

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

14 Jan 0072

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5330-00-488-3882 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KZ
Code Definitions

KZ

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5330-00-488-3882 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADYTCenter Hole Diameter3.094 INCHES MINIMUM AND 3.124 INCHES MAXIMUM
AAGRCross-Sectional Shape StyleO-RING
ADVNCross-Sectional Height0.135 INCHES MINIMUM AND 0.143 INCHES MAXIMUM
CQFMHardness Rating70.0 SHORE DUROMETER A MINIMUM OVERALL AND 80.0 SHORE DUROMETER A MAXIMUM OVERALL
MATTMaterialRUBBER FLUOROCARBON CLASS FPM OVERALL
MDCLMaterial Document And ClassificationAMS-7278 ASSN STD SINGLE MATERIAL RESPONSE OVERALL