5340-00-323-1368

CLAMP,LOOP


5340-00-323-1368 (5340003231368, 003231368)
Part Number (1 listing): 789-19T
Summary

FSG 53 / FSC 5340

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 24 Nov 1973

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5340-00-323-1368 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
789-19T3 - Design Control Reference2 - Production ItemTRANSDIGM INC  83930    CAGE 83930  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5340-00-323-1368 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
535340003231368A1270017532XKAPU24 Nov 1973
Code Definitions

53

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Hardware and Abrasives

5340

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Hardware, Commercial

003231368

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5340-00-323-1368

A12700

Federal Item Identification Guide (FIIG_4065)

17532

Item Naming Code (INC_4080)

24 Nov 1973

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5340-00-323-1368 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5340-00-323-1368 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3324SBD789-19T  83930   CAGE/83930
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5340-00-323-1368 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2KZ029 Mar 1975
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KZ

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

29 Mar 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5340-00-323-1368 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KZ
Code Definitions

KZ

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5340-00-323-1368 Submit RFQ
MRCDecoded RequirementClear Text Reply
AZDCDistance From Loop Center To Tongue End1.469 INCHES NOMINAL
BZTPDistance From Outer Edge Of Lug To Hole Center0.250 INCHES NOMINAL
AZCYCenter To Center Distance Between Loop And Mounting Hole0.984 INCHES NOMINAL
AZDECenter To Center Distance Between Loop And Lug Hole1.094 INCHES NOMINAL
AAAPCushioning Environmental ProtectionANY ACCEPTABLE
ABMZDiameter0.199 INCHES NOMINAL
ABPXMaterial Thickness0.062 INCHES NOMINAL
MATTMaterialRUBBER SYNTHETIC CUSHION
MATTMaterialSTEEL BAND
BZTNLoop Inside Diameter1.188 INCHES NOMINAL
BZTQLug Hole Diameter0.199 INCHES NOMINAL
AHMMLug Width0.500 INCHES NOMINAL
ABMKOverall Width0.625 INCHES NOMINAL
STYLStyle DesignatorRIGHT HAND CLAMP & BRACKET
STDCSurface Treatment Document And ClassificationQQ-P-416 TY 2 CL2 FED SPEC ALL TREATMENT RESPONSES BAND
SFTTSurface TreatmentCHROMATE BAND AND CADMIUM BAND
AAALTongue Hole TypeROUND, UNTHREADED


Back to Top
Back to Top