5360-00-527-1317

SPRING,HELICAL,COMPRESSION


5360-00-527-1317 (5360005271317, 005271317)
Part Numbers (55 listings): 1388618 | 39J908PC16 | 39J942PC49 | 1336829 | W8453932PC22 | W5599149PC48 | W5599049SH1PC123 | W5586199SH1PC41 | W5586030PC16 | W5586119PC16 | W6680731PC16 | WW8453346PC16 | WW8453365PC49 | WW8453365SH2PC49 | WW8453365SH1PC49 | WW8453786PC49 | WW8454437PC21 | WW8454340PC51 | WW8440340PC16 | WW8440360PC41 | WW8497560PC21 | WW8454526PC16 | WW8454658PC22 | W5544155PC39 | W5544135PC16 | W5547032PC16 | W4838828PC16 | W4838647PC16 | W4843818PC16 | W4869042SH2PC8 | W4869042SH1PC8 | W5547542PC16 | 101A751AA | WW6667899SH1PC70 | WW6683539PC21 | WW6683726ITEM21 | WW6680755PC31 | WW6665748PC69 | WW6665755PC68 | WW6665740PC16 | WW6665773PC75 | WW6665769PC11 | WW6664180PC75 | WW6665599PC168 | WW6664278PC71 | WW6665530PC16 | WW6664268PC92 | WW5599030PC16 | WW5599119PC16 | WW5587399SH1PC45 | WW5547597PC28 | WW5547592PC28 | 6658914 | 81C178PC10 | 101AG51AA |
Summary

FSG 53 / FSC 5360

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5360-00-527-1317 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
13886183 - Design Control Reference9 - No Longer UsedWESTINGHOUSE ELECTRIC CORP  11660    CAGE 11660  
13886185 - Replaced / Discontinued2 - Production ItemWESTINGHOUSE ELECTRIC CORP  79500    CAGE 79500  
39J908PC165 - Replaced / Discontinued2 - Production ItemWESTINGHOUSE ELECTRIC CORP  79500    CAGE 79500  
39J942PC495 - Replaced / Discontinued2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  90099    CAGE 90099  
13368295 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W8453932PC225 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W5599149PC485 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W5599049SH1PC1235 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W5586199SH1PC415 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W5586030PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W5586119PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W6680731PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW8453346PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW8453365PC495 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW8453365SH2PC495 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW8453365SH1PC495 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW8453786PC495 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW8454437PC215 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW8454340PC515 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW8440340PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW8440360PC415 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW8497560PC215 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW8454526PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW8454658PC225 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W5544155PC395 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W5544135PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W5547032PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W4838828PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W4838647PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W4843818PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W4869042SH2PC85 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W4869042SH1PC85 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
W5547542PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
101A751AA5 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6667899SH1PC705 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6683539PC215 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6683726ITEM215 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6680755PC315 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6665748PC695 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6665755PC685 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6665740PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6665773PC755 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6665769PC115 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6664180PC755 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6665599PC1685 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6664278PC715 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6665530PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW6664268PC925 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW5599030PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW5599119PC165 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW5587399SH1PC455 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW5547597PC285 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
WW5547592PC285 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
66589145 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
81C178PC105 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
39J908PC165 - Replaced / Discontinued9 - No Longer UsedWESTINGHOUSE ELECTRIC CORP  11660    CAGE 11660  
39J942PC495 - Replaced / Discontinued9 - No Longer UsedWESTINGHOUSE ELECTRIC CORP  11660    CAGE 11660  
13368295 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W5599149PC485 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W5599049SH1PC1235 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W6680731PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
101A751AA5 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W8453932PC225 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW8453346PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW8453365PC495 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW8453365SH1PC495 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW8453365SH2PC495 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW8453786PC495 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW8454526PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW8454340PC515 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW8454437PC215 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW8454658PC225 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW8497560PC215 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W4838647PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W4838828PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W4843818PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W4869042SH2PC85 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W4869042SH1PC85 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W5586199SH1PC415 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W5586119PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W5586030PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W5547542PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W5547032PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W5544155PC395 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
W5544135PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW8440340PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW8440360PC415 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6683726ITEM215 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6683539PC215 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6667899SH1PC705 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6680755PC315 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6665740PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6665599PC1685 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6665748PC695 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6665755PC685 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6665769PC115 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6665773PC755 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6664180PC755 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6665530PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6664278PC715 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW6664268PC925 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW5599119PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW5587399SH1PC455 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW5599030PC165 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW5547592PC285 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
WW5547597PC285 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
66589145 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
81C178PC105 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  71669    CAGE 71669  
39J942PC495 - Replaced / Discontinued9 - No Longer UsedWESTINGHOUSE ELECTRIC CORP  79500    CAGE 79500  
101AG51AAC - Advisory Reference1 - Incomplete Part NumberBOSCH REXROTH GMBH LOHMANN  D9182    CAGE D9182  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5360-00-527-1317 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
535360005271317A0290004226XKANU1 Jan 1963
Code Definitions

53

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Hardware and Abrasives

5360

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Coil, Flat, Leaf, and Wire Springs

005271317

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5360-00-527-1317

A02900

Federal Item Identification Guide (FIIG_4065)

04226

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5360-00-527-1317 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZH011 Apr 1991
ZU011 Apr 1991
ZW011 Nov 1998
YA011 Dec 2001
N9BZN9ZD3HZHDHD1 Aug 2005
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

HD

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5360-00-527-1317 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
526AX39J942PC49  90099   CAGE/90099
359XAXB39J942PC49  79500   CAGE/79500
C16ZZAC101AG51AA  D9182   CAGE/D9182
Code Definitions

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

AX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43216-5000

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

X

Document Availability Code (DAC_2640)


DAC not known. Found on U.S. NSNs that were assigned before 1975. Cannot be used for new item assignment, or any maintenance action on older NSNs.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

AC

Service / Agency Designator Code (SADC_4672)


Navy


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5360-00-527-1317 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2KZ09 Jul 1981
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KZ

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

9 Jul 1981

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5360-00-527-1317 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
579Z9ABZW177940X87400SPRINGS-SPRINGS-NOI
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


579

Water Commodity Code (WRT_CMDTY_CD_9275)


Steel Springs, (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

177940

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

87400

Uniform Freight Classification (UFC_CD_MODF_3040)

SPRINGS-SPRINGS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5360-00-527-1317 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSJU1EA0
DSSMSJU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5360-00-527-1317 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP42XXX
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
X00EQM
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

42

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Container, watervaporproof bag, sealed, container

XXX

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

E

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5360-00-527-1317 Submit RFQ
MRCDecoded RequirementClear Text Reply
AXLHCoil Helix DirectionRIGHT-HAND
APCNCoil Quantity9
ABQKEnd StyleSPRING END,SQUARED AND GROUND BOTH ENDS
MATTMaterialSTEEL OVERALL
AARXInside Diameter0.402 INCHES NOMINAL
AGEKSpring Free Length1.500 INCHES NOMINAL
AXLPSpring Deflection Rate6.400 POUNDS PER INCH NOMINAL
AXLQSpring Free Outside Diameter0.484 INCHES NOMINAL
AXJQSpring Solid Length0.375 INCHES NOMINAL
STYLStyle DesignatorCYLINDRICAL
SFTTSurface TreatmentCADMIUM OVERALL AND ZINC OVERALL


Back to Top