5445-00-292-9931

TOWER


5445-00-292-9931 (5445002929931, 002929931)
Part Number (1 listing): MILT9524
Summary

FSG 54 / FSC 5445

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1961

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5445-00-292-9931 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
MILT95244 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
Code Definitions

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5445-00-292-9931 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
545445002929931T324-K02392X1ANA1 Jan 1961
Code Definitions

54

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Prefabricated Structures and Scaffolding

5445

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Prefabricated Tower Structures

002929931

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5445-00-292-9931

T324-K

Federal Item Identification Guide (FIIG_4065)

02392

Item Naming Code (INC_4080)

1 Jan 1961

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5445-00-292-9931 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZT
ZW
ZT011 Apr 1991
ZW011 Nov 2005
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5445-00-292-9931 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3413TGDMILT9524  81349   CAGE/81349
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TG

Reference Number Action Activity Code (RNAAC_2900)


Warner-Robins Air Logistics Center, Robins AFB, GA 31098-5609

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 5445-00-292-9931 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
T5742ZZBZT187010X92020TOWERS-NOI-STL-WD-SEP-COMB-KD
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


T

Less Than Carload (LCL_CD_2760)


55

574

Water Commodity Code (WRT_CMDTY_CD_9275)


Iron or Steel, Structural, (less than 35 feet) (See 825)

2

Type Cargo Code (TYPE_CGO_CD_9260)


Type cargo code not applicable (for Air Force internal use).

Z

Special Handling Code (SP_HDLG_CD_9240)


No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.

Z

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation, but does exceed 72 inches in one or more dimensions.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

187010

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

92020

Uniform Freight Classification (UFC_CD_MODF_3040)

TOWERS-NOI-STL-WD-SEP-COMB-KD

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5445-00-292-9931 Submit RFQ
MRCDecoded RequirementClear Text Reply
CCMYElevating FacilityHOIST ASSEMBLY
ALPMAssembly FormKNOCKED-DOWN
CCMHBottom Length4.000 FEET NOMINAL
AQTWBottom Width4.000 FEET
CCMMCabinNOT INCLUDED
AXQDCapacity20000.0 POUNDS
CCMKClimbing FacilityLADDER
AERKGrounding ProvisionINCLUDED
HGTHHeight48.000 FEET NOMINAL
MATTMaterialSTEEL
ZZZTNondefinitive Spec/Std DataAAB-435/GR TYPE
CCMXLightning RodINCLUDED
CCMLRest Platform Quantity1
SHPEShapeSQUARE
CCMGSupported Item NameANTENNA
SFTTSurface TreatmentPAINT
ARRWTop Width4.000 FEET NOMINAL
CCMJTop Length4.000 FEET NOMINAL


Back to Top
Back to Top