Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
SSP361TYPE1CLASS1 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | FEDERAL SPECIFICATIONS | 81348 | ![]() |
SSP361TYPE1CLASS1 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | FEDERAL SPECIFICATIONS | 81348 | ![]() |
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
56 | 5630 | 002574098 | T331-B | 09862 | X | 1 | A | N | A | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | D4 | 6 | 3 | D4 | 0 | 1 Jan 1964 | 5630008255709 | 8 Oct 1965 |
1 | D4 | 6 | 3 | D4 | 0 | 1 Jan 1964 | 5630008492293 | 8 Oct 1965 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
U.S. Army Belvoir Research, Development and, Engineering Center, Fort Belvoir, VA 22060-5606
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
736 | Z | 9 | A | B | Z | S | 050620 | X | 29100 | PIPE-SEWER-R-FITTINGS |
Plumbing Supplies
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
60
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
BPNL | End Joint Type | BELL-SPIGOT |
ZZZT | Nondefinitive Spec/Std Data | 1 TYPE AND 1 CLASS |
AARX | Inside Diameter | 12.000 INCHES NOMINAL |
BPNJ | Laying Length | 3.000 FEET NOMINAL |
BPNS | Vitrification | PROVIDED |
ANNJ | Strength Designation | STANDARD |