5640-01-540-0843

INSULATION BLANKET,THERMAL


5640-01-540-0843 (5640015400843, 015400843)
Part Number (1 listing): 230-00033CD
Summary

FSG 56 / FSC 5640

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 9 May 2006

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5640-01-540-0843 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
230-00033CD3 - Design Control Reference2 - Production ItemHDT EXPEDITIONARY SYSTEMS, INC.  0WJE1      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5640-01-540-0843 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
565640015400843T230-B15120X46APAA09 May 2006
Code Definitions

56

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Construction and Building Materials

5640

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Wallboard, Building Paper, and Thermal Insulation Materials

015400843

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5640-01-540-0843

T230-B

Federal Item Identification Guide (FIIG_4065)

15120

Item Naming Code (INC_4080)

9 May 2006

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5640-01-540-0843 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
A19000ZCDCL1 Mar 2014
G751001 Mar 2014
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

CD

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army War Reserve Command, New Cumberland, PA 17070-5008

CL

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006


FLIS - SEG C - REFERENCE NUMBER | NSN 5640-01-540-0843 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZ230-00033CD  0WJE1  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5640-01-540-0843 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59769 May 2006
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

9 May 2006

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5640-01-540-0843 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
PA845Z9A2ZC103300C53360INSULATING-MATERIAL-NOI-SUB3
Code Definitions

PA

Originating Activity Code (ORIG_ACTY_CD_4210)


Marine Corps Logistics Base, Albany, GA 31704-1128

845

Water Commodity Code (WRT_CMDTY_CD_9275)


Plastic Fabricated Materials, incl Containers, Pallets, Sheets and other Plastic Material

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

2

Air Commodity Code (AIR_CMTY_HDLG_9215)


Arms/Weapons (all types including Inert Component Parts).

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

C

Less Than Truckload (CLAS_RTNG_CD_2770)


250

103300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

C

NMFC Sub Item Number (SUB_ITM_NBR_0861)

53360

Uniform Freight Classification (UFC_CD_MODF_3040)

INSULATING-MATERIAL-NOI-SUB3

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5640-01-540-0843 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DAGSAJU0ZEA0
TGGSAJU0EA0
Code Definitions

GSA

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


General Services Administration, Washington, D.C. 20406

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

TG

Service / Agency Code (MOE_CD_2833)


General Services Administration


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5640-01-540-0843 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationAIR CONDITIONER,1.5 TON,60 HZ HORIZONTAL
ABRYLength22.5 INCHES NOMINAL
CXCYPart Name Assigned By Controlling Agency1/2 IN INSULAT
FEATSpecial FeaturesMATERIAL:AP ARMAFLEX, CLOSED CELL; ADHESIVE ATTACHMENT ONE SIDE; OPPOSITE ADHESIVE SIDE IS 5-PLY LAMINATE, 3 MIL THICK; HEAT SHIELD OPPOSITE ADHESIVE SIDE
ABGLWidth9.625 INCHES NOMINAL
ABNMThickness0.5 INCHES NOMINAL


Back to Top
Back to Top