5670-00-476-5311

SCREEN,WINDOW,METAL


5670-00-476-5311 (5670004765311, 004765311)
Part Numbers (2 listings): WS2B | 399349 |
Summary

FSG 56 / FSC 5670

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 11 Jun 1971

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5670-00-476-5311 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
WS2B3 - Design Control Reference9 - No Longer UsedPENNSYLVANIA ALUMINUM WINDOW CO  19350      
WS2B3 - Design Control Reference9 - No Longer UsedPENNSYLVANIA ALUMINUM WINDOW CO  19350      
399349C - Advisory Reference1 - Incomplete Part NumberEATON AEROSPACE LLC  62983    CAGE 62983  
399349C - Advisory Reference1 - Incomplete Part NumberEATON AEROSPACE LLC  62983    CAGE 62983  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5670-00-476-5311 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
565670004765311T231-E04503X1ANA11 Jun 1971
Code Definitions

56

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Construction and Building Materials

5670

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Building Components, Prefabricated

004765311

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5670-00-476-5311

T231-E

Federal Item Identification Guide (FIIG_4065)

04503

Item Naming Code (INC_4080)

11 Jun 1971

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG C - REFERENCE NUMBER | NSN 5670-00-476-5311 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
339475DWS2B  19350  
C11ZZAC399349  62983   CAGE/62983
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

AC

Service / Agency Designator Code (SADC_4672)


Navy


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5670-00-476-5311 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59891 Feb 1975
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

98

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

9

NIIN Status Code (NIIN_STAT_CD_2670)


Item has been determined by a U.S. activity to be nonprocurable, and is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). If procurement sources are determined, submit a request to change the NIIN Status Code. See volume 4, chapter 4.16.Item is nonprocurable.Item has been determined by a U.S. activity to be nonprocurable, and is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). If procurement sources are determined, submit a request to change the NIIN Status Code. Item is nonprocurable.

1 Feb 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5670-00-476-5311 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
75576Z9ABZW035315Z16255SCREEN-DOORS-OR-WINDOW-SCREENS-NOI
Code Definitions

75

Originating Activity Code (ORIG_ACTY_CD_4210)


GSA, FSS/FCSC Washington, DC 20406

576

Water Commodity Code (WRT_CMDTY_CD_9275)


Metal and Metal Products, (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

035315

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

16255

Uniform Freight Classification (UFC_CD_MODF_3040)

SCREEN-DOORS-OR-WINDOW-SCREENS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5670-00-476-5311 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADNMFrame MaterialALUMINUM
ALDFFrame TypeCHANNEL
ALKEFrame Width40.875 INCHES NOMINAL
BLGZFrame Height23.938 INCHES NOMINAL
BLHBFrame Thickness0.438 INCHES NOMINAL
BLHCWire Cloth MaterialALUMINUM
BNGDMesh Count18 PER INCH
FEATSpecial FeaturesTOP HUNG; SIDE PLUNGERS


Back to Top
Back to Top