Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
IMSSEPTRANSC1009 | 3 - Design Control Reference | 2 - Production Item | U S SPECIAL OPERATIONS COMMAND | 41CT5 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
58 | 5810 | 015785781 | A511L0 | 40928 | X | 4 | 3 | C | N | A | A | 0 | 13 Oct 2009 |
Communication, Detection, and Coherent Radiation Equipment
Communications Security Equipment and Components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
MLI (SME) — Remove and/or demilitarize installed key point(s) as prescribed in DOD 4160.21-M-1 — Defense Demilitarization Manual, or lethal parts, components and accessories
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A102 | A103 | 0 | 0 | 0 | E | CN | BS | 1 Sep 2011 | ||||||||||||||||||||||
F8SQ | FOO4 | 0 | 0 | 0 | E | CN | TO | 1 Sep 2011 | ||||||||||||||||||||||
MS22 | 0 | 0 | 0 | E | CN | 1 Sep 2011 | ||||||||||||||||||||||||
NJQ4 | 0 | 0 | 0 | E | CN | 1 Sep 2011 | ||||||||||||||||||||||||
SC01 | 0 | 0 | P | E | CN | 1 Sep 2011 |
Not Established
DLIS File Conversion Code. This code was assigned by DLIS to existing wholesale interservice supply support agreement (WISSA) type recording (LOA 8D) during initial file conversion program. This code is reassigned to code 1, 2, 3, 5, 6 or 8 upon completion of item review. The SICA CMD will reflect the SOS/SOSM and AAC compatible with the PICA. The PICA will not be entered in the DAAS IMM field.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Total depot maintenance is being accomplished by commercial contract.
Contract, Contiguous United States (CONUS)
Special Operations Force Support Agency (SOFSA) Lexington, KY 40516-9723
USAMC Data Management Center, Redstone Arsenal, AL 35898-5239
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 5 | ZZ | IMSSEPTRANSC1009 | 41CT5 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 13 Oct 2009 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TK |
HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | H9D | Y | 9 | 0 | EA | 0 | ||
DF | H9D | Y | 9 | 0 | S | EA | 0 | |
DJ | H9D | Y | 9 | 0 | EA | 0 | ||
DM | H9D | Y | 9 | 0 | EA | 0 | ||
DN | H9D | Y | 9 | 0 | H | EA | 0 |
Special Operations Forces Support Activity (SOFSA), BLDG 220, 5749 Briar Hill Rd, Lexington, KY 40516-9721
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
This code identifies an item as a Controlled Cryptographic Item (CCI). CCI is described as secure telecommunications or information handling equipment, associated cryptographic component, or other hardware item which performs a critical COMSEC function. Items so designated are unclassified but controlled, and will bear the designation “Controlled Cryptographic Item or CCI.”
No QUP
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC ND2: AF Equipment Management System (AFEMS); NAVY: Slow Demand Velocity Items (Consumables)
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
Department of the Army
Department of the Air Force
HQ United States Special Operations Command (HQ USSOCOM)
U.S. Marine Corps
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
FEAT | Special Features | INTERIM MOBILE STRATEGIC SATELLITE ENTRY POINT (IMSSEP) COMMUNICATIONS SECURE TERMINAL, TRANSPORT CORE IS THE NETWORK BACKBONE FOR ALL DATA TRANSPORTED THROUGH THE MSSEP. IT PROVIDES MODEM SIGNAL PROCESSING AND ROUTING OF ENCRYPTED DATA. IT INTERFACES WITH THE SYSTEM'S SATCOM ANTENNA(S), RED/BLACK/GREYSERVICES, AND OTHER TRANSPORT CIRCUITS AS REQUIRED. THE INTERIM-MSSEP TRANSPORT CORE INCLUDES 11 TRANSIT CASES: CASE 1 HAS TIMING DIVISION MULTIPLE ACCESS CENTRAL SERVER; CASE 2 HAS ONE EA SATELLITE MODEM 5895-01-519-2415, TIMING SOURCE, INTERFACE UNIT, ADP 7025-01-546-1694; CASE 3 HAS 2 EA SERVER ADP 7035-01-572-1045; 1 EA INTERFACE UNIT, ADP 7025-01-534-9329; CASE 4 HAS 2 EA SERVER ADP 7035-01-572-1045; CASE 5 HAS 2 EA SERVER ADP 7035-01-572-1045; CASE 6 HAS 2 EA SERVER ADP 7035-01-572-1045; CASE 7 HAS INTERFACE UNIT, ADP 7025-01-577-3197; CASES 8, 9, 10, & 11 HAVE ONE POWER SUPPLY IN EA 6130-01-560-7789 |