5815-00-401-9721

RADIO TELETYPEWRITER SET


5815-00-401-9721 (5815004019721, 004019721)
Part Numbers (2 listings): PPL4399 | ANVRC29 |
Summary

FSG 58 / FSC 5815

DEMIL: D

DEMIL INT: 1

HMIC: N

Date Created: 8 Apr 1970

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5815-00-401-9721 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
PPL43993 - Design Control Reference2 - Production ItemUS ARMY COMMUNICATIONS &  80063    CAGE 80063  
ANVRC295 - Replaced / Discontinued1 - Incomplete Part NumberJOINT ELECTRONICS TYPE DESIGNATION  80058    CAGE 80058  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5815-00-401-9721 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
585815004019721T198-B19534X1DNU8 Apr 1970
Code Definitions

58

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Communication, Detection, and Coherent Radiation Equipment

5815

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Teletype and Facsimile Equipment

004019721

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5815-00-401-9721

T198-B

Federal Item Identification Guide (FIIG_4065)

19534

Item Naming Code (INC_4080)

8 Apr 1970

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5815-00-401-9721 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Aug 1995
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5815-00-401-9721 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3326CLDPPL4399  80063   CAGE/80063
3514CLDANVRC29  80058   CAGE/80058
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

CL

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5815-00-401-9721 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
697015 Aug 1983
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

15 Aug 1983

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5815-00-401-9721 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CLAYQ72D49AHDJ116250X59490TYPEWRITERS-TELETYPEWRITERS-PARTS1
Code Definitions

CL

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

AY

Hazardous Materiel Code (HMC_2720)


Radioactive material, n.o.s.

Q

Less Than Carload (LCL_CD_2760)


70

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

4

Type Cargo Code (TYPE_CGO_CD_9260)


Radioactive Material (no label required)

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

D

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Hazardous material (not required hand to hand receipt) including all regulated items other than special weapons and their components.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

116250

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

59490

Uniform Freight Classification (UFC_CD_MODF_3040)

TYPEWRITERS-TELETYPEWRITERS-PARTS

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5815-00-401-9721 Submit RFQ
MRCDecoded RequirementClear Text Reply
AJKADocument IdentificationPPL4399
AJJYDocument Source80063
AJJZDocument TypePROCUREMENT PARTS LIST
APWSEmission TypeA1 RECEIVING AND A1 TRANSMITTING AND A3 RECEIVING AND A3 TRANSMITTING AND F1 RECEIVING AND F1 TRANSMITTING
AJJXComponent Document OriginGOVERNMENT
ACYRDc Voltage Rating28.5 VOLTS NOMINAL
APWQFrequency Band Type And Quantity10 RECEIVING AND 10 TRANSMITTING
APWRFrequency Channel Type And Quantity8 RECEIVING AND 8 TRANSMITTING
AEHXMaximum Power Dissipation Rating100.0 WATTS
ALSFInternal Battery AccommodationNOT INCLUDED
AKWBJoint Electronics Type Designation System Item Type NumberAN/VRC-29
AKWAJoint Electronics Type Designation System Item NameRADIO SET
APWNReceiver Frequency Rating1.5 MEGAHERTZ MINIMUM AND 20.0 MEGAHERTZ MAXIMUM
APWPTransmitter Frequency Rating1.5 MEGAHERTZ MINIMUM AND 20.0 MEGAHERTZ MAXIMUM


Back to Top