5820-00-030-0155

RADIO SET


5820-00-030-0155 (5820000300155, 000300155)
Part Number (1 listing): ANGRC19
Summary

FSG 58 / FSC 5820

DEMIL: D

DEMIL INT: 1

HMIC: P

Date Created: 1 Nov 1967

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5820-00-030-0155 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
ANGRC193 - Design Control Reference2 - Production ItemJOINT ELECTRONICS TYPE DESIGNATION  80058    CAGE 80058  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5820-00-030-0155 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
585820000300155T198-B19533X1DPA1 Nov 1967
Code Definitions

58

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Communication, Detection, and Coherent Radiation Equipment

5820

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Radio and Television Communication Equipment, Except Airborne

000300155

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5820-00-030-0155

T198-B

Federal Item Identification Guide (FIIG_4065)

19533

Item Naming Code (INC_4080)

1 Nov 1967

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5820-00-030-0155 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZH011 Apr 1991
ZU011 Apr 1991
ZW011 Dec 1995
WB011 Feb 2005
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5820-00-030-0155 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3324SXDANGRC19  80058   CAGE/80058
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

SX

Reference Number Action Activity Code (RNAAC_2900)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5820-00-030-0155 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
697015 Aug 1983
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

15 Aug 1983

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5820-00-030-0155 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SXW758N9AHDW062820Z35080RADIO-TV-TRANSMIT-RECEIVE-SETS1
Code Definitions

SX

Originating Activity Code (ORIG_ACTY_CD_4210)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

W

Less Than Carload (LCL_CD_2760)


Rating Variable

758

Water Commodity Code (WRT_CMDTY_CD_9275)


Radios, Televisions, Record Players, Tape Recorders (See 773 and 774)

N

Type Cargo Code (TYPE_CGO_CD_9260)


Dangerous materiel in limited quantities (no label required)

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

D

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Hazardous material (not required hand to hand receipt) including all regulated items other than special weapons and their components.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062820

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35080

Uniform Freight Classification (UFC_CD_MODF_3040)

RADIO-TV-TRANSMIT-RECEIVE-SETS

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5820-00-030-0155 Submit RFQ
MRCDecoded RequirementClear Text Reply
AJKADocument IdentificationSIG 7 AND 8 AN/GRC19
AJJZDocument TypeSUPPLY MANUAL
AKWCElectrical Power Source RelationshipOPERATING
APWSEmission TypeA1 TRANSMITTING AND A3 TRANSMITTING AND F1 TRANSMITTING AND A1 RECEIVING AND A2 RECEIVING AND A3 RECEIVING AND F1 RECEIVING
AJJXComponent Document OriginGOVERNMENT
ACYRDc Voltage Rating28.0 VOLTS NOMINAL
APWQFrequency Band Type And Quantity10 RECEIVING AND 32 TRANSMITTING
APWRFrequency Channel Type And Quantity8 TRANSMITTING
AEHXMaximum Power Dissipation Rating100.0 WATTS
ZZZTNondefinitive Spec/Std DataAN/GRC-19 TYPE
ZZZVFsc Application DataRADIO EXCEPT NAVIGATION AND HOME TYPE,NONAIRBORNE
ALSFInternal Battery AccommodationNOT INCLUDED
AKWBJoint Electronics Type Designation System Item Type NumberTYPE NO. AN/GRC-19
AKWAJoint Electronics Type Designation System Item NameRADIO SET
APWNReceiver Frequency Rating0.5 MEGAHERTZ MINIMUM AND 32.0 MEGAHERTZ MAXIMUM
APWPTransmitter Frequency Rating1.5 MEGAHERTZ MINIMUM AND 20.0 MEGAHERTZ MAXIMUM


Back to Top