Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
C5156500-2 | 3 - Design Control Reference | 9 - No Longer Used | SIGNALS WARFARE PROJECT MANAGER | 57958 | |
AN/PRD-12 | 5 - Replaced / Discontinued | 2 - Production Item | JOINT ELECTRONICS TYPE DESIGNATION | 80058 | |
C5156500-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | SIGNALS WARFARE PROJECT MANAGER | 57958 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
58 | 5825 | 012986961 | 19509 | 2 | 6 | C | N | A | A | 0 | 20 Apr 1989 |
Communication, Detection, and Coherent Radiation Equipment
Reference Item Identification
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
MLI (SME) — Remove and/or demilitarize installed key point(s) as prescribed in DOD 4160.21-M-1 — Defense Demilitarization Manual, or lethal parts, components and accessories
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A502 | A802 | 0 | 0 | A | D | TB | 1 Aug 2001 | |||||||||||||||||||||||
MA46 | 0 | 0 | 3 | D | TB | 1 Aug 2001 |
Not Established
An activitiy within the Army is providing depot maintenance support.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
End Item Primary Inventory Control Activity. This code identifies SICA managed end items or equipment assigned to another service PICA that is responsible for the wholesale logistics support functions of single submitter of cataloging data, acquisition and disposal authority and depot maintenance, if required, to be provided by DMISA. Supply support requirements will be submitted by the SICA to the PICA on MIPRs unless otherwise directed by the PICA. The SICA is responsible for the wholesale stock, store, and issue functions for SICA activities. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Tobyhanna Army Depot (TYAD), PA
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 22 Apr 1989 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
72D | Z | 9 | A | H | C | W | 062820 | Z | 35080 | RADIO-TV-TRANSMIT-RECEIVE-SETS |
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Chemical corps items and all other chemicals not covered in other classifications. When chemical item (as indicated by the DOT Proper Shipping Name) is sensitive as defined in Appendix A Section I of DoD 4500.32ûR, Volume 1, second position must be from table 85, part 1.
Variable Rating
No Variation. NMFC and UFCC Match.
Commanding General, Marine Corps Logistics Command, 566–2, Bldg. 3700, Albany, GA 31704-5000
INVENTORY CONTROL POINT (ICP)-REGULATED (Service/Agency use only.) Issue, transfer, or shipment is controlled by the ICP. 1. The use or stockage of the item requires release authority based on prior or concurrent justification. 2. Requisitions will be submitted in accordance with Agency/Service requisitioning procedure.
Communication/electronic equipment and parts
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
US Army Communications-Electronics, Command and Fort Monmout, Fort Monmouth, NJ 07703-5016
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
U.S. Marine Corps
Department of the Army