Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
8282 | 3 - Design Control Reference | 9 - No Longer Used | EMERSON ELECTRIC CO | 80089 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5950 | 001843679 | A058B0 | 00780 | X | 1 | A | P | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR01 | 1 Jul 1997 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 13 Jun 1967 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 595 | Z | 9 | A | H | Z | W | 063420 | Z | 35355 | TRANSFORMERS-NOI-OR-TRANSFORMER-PAR |
77.5
Transformer, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 1.500 INCHES NOMINAL |
ADAQ | Body Length | 1.688 INCHES NOMINAL |
ADAT | Body Width | 1.375 INCHES NOMINAL |
AEJN | Distance Between Mounting Facility Centers | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | Frequency Rating | 200.0 HERTZ MINIMUM AND 3.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
ACZF | Maximum Transformer Power Rating | 500.0 MILLIWATTS SINGLE COMPONENT |
AKPV | Mounting Facility Quantity | 2 SINGLE GROUP |
AXGY | Mounting Method | FLANGE AND UNTHREADED HOLE SINGLE GROUP |
ACYE | Transformer Function | INTERSTAGE |
ACYW | Impedance Rating In Ohms | 75.0 NOMINAL AND 1000.0 NOMINAL AND 3000.0 NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
ACYW | Impedance Rating In Ohms | 750.0 NOMINAL AND 3000.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
AKNA | Inclosure Type | FULLY INCLOSED |
ACZH | Primary To Secondary Turn Ratio | 1 TO 1 SINGLE COMPONENT |
AARG | Reliability Indicator | NOT ESTABLISHED |
FEAT | Special Features | CASE METAL MATERIAL |
BPLC | Winding Function And Quantity | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
TTQY | Terminal Type And Quantity | 7 SOLDER STUD |