Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
43467 | 3 - Design Control Reference | 2 - Production Item | EXELIS INC. | 24930 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
58 | 5840 | 006433812 | A39900 | 00740 | X | M | 9 | B | N | U | 1 Jan 1963 |
Communication, Detection, and Coherent Radiation Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZP01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TU | 0 | 14 May 2008 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M | 658 | Z | 9 | A | H | Z | M | 062900 | X | 35110 | RECTIFIERS-NOI-BATTERY-ELIMINATORS |
85
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CBBL | Features Provided | FILTER |
ZZZV | Fsc Application Data | RADAR SET,RADAR SEARCH EQUIPMENT,EXCEPT AIRCRAFT |
CWGH | Output Current Rating | 200.0 DC MILLIAMPERES MINIMUM SINGLE POWER OUTPUT AND 500.0 DC MILLIAMPERES MAXIMUM SINGLE POWER OUTPUT |
APPA | Output Voltage Rating | 250.0 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 105.0 DC VOLTS MAXIMUM SINGLE POWER OUTPUT |
APNX | Input Voltage Rating | 117.0 AC POUNDS PER HOUR WET 1ST OPERATING POWER RQMT |
APTQ | Input Frequency Rating | 60.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE SINGLE OPERATING POWER RQMT |
APNX | Input Voltage Rating | -150.0 DC POUNDS PER HOUR WET 6TH OPERATING POWER RQMT |
APNX | Input Voltage Rating | -450.0 DC POUNDS PER HOUR WET 4TH OPERATING POWER RQMT |
APNX | Input Voltage Rating | -300.0 DC POUNDS PER HOUR WET 5TH OPERATING POWER RQMT |
APNX | Input Voltage Rating | 300.0 DC POUNDS PER HOUR WET 3RD OPERATING POWER RQMT |
APNX | Input Voltage Rating | 350.0 DC POUNDS PER HOUR WET 2ND OPERATING POWER RQMT |
BHQN | Rectification Method | FULL WAVE VOLTAGE DOUBLER |
ABKW | Overall Height | 8.688 INCHES NOMINAL |
ABHP | Overall Length | 19.500 INCHES NOMINAL |
ABMK | Overall Width | 19.313 INCHES NOMINAL |