5855-01-459-0625

IMAGE INTENSIFIER,NIGHT VISION


5855-01-459-0625 (5855014590625, 014590625)
Part Number (1 listing): ITT271296
Summary

FSG 58 / FSC 5855

DEMIL: C

DEMIL INT:

HMIC: N

Date Created: 18 Sep 1998

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5855-01-459-0625 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
ITT2712963 - Design Control Reference2 - Production ItemEXELIS INC.  13567      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5855-01-459-0625 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
585855014590625A2390061957X42CNAA018 Sep 1998
Code Definitions

58

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Communication, Detection, and Coherent Radiation Equipment

5855

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Night Vision Equipment, Emitted and Reflected Radiation

014590625

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5855-01-459-0625

A23900

Federal Item Identification Guide (FIIG_4065)

61957

Item Naming Code (INC_4080)

18 Sep 1998

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

2

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


The approved item name applied to this item exists for use exclusively with the partial descriptive method of item identification - Miscellaneous Items Federal Item Identification Guide A239.

C

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Remove and/or demilitarize installed key point(s) as prescribed in DOD 4160.21-M-1 — Defense Demilitarization Manual, or lethal parts, components and accessories

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5855-01-459-0625 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZA0118 Sep 1998
YB011 Nov 2014
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5855-01-459-0625 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDITT271296  13567  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5855-01-459-0625 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597018 Sep 1998
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

18 Sep 1998

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5855-01-459-0625 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZA
Code Definitions

ZA

Originating Activity Code (ORIG_ACTY_CD_4210)


Australia

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5855-01-459-0625 Submit RFQ
MRCDecoded RequirementClear Text Reply
TEXTGeneral Characteristics Item DescriptionSINGLE MONOCULAR VERSION OF INTERNATIONAL TECHNOLOGIES (LASER) MINI N/SEAS; THIRD GENERATION IMAGE INTENSIFIER; ACCESSORIES SUPPLIED - HEAD HARNESS ASSEMBLY, HELMET MOUNT (KEVLAR HELMET), OPERATOR'S PLACARD, OPERATOR'S HANDBOOK, AND TRANSIT CASE; TWO MONOCULARS MAY BE CONNECTED TO MAKE BINOCULAR; COLOR - MATT BLACK; RESOLUTION NOT LESS THAN 0.8 LINE PAIRS PER MILLIRADIAN FOR TARGET TO BACKGROUND CONTRAST AT MINIMUM 95 PERCENT WITH SCENE ILLUMINATION OF 10 (TO THE NEGATIVE 3 POWER) LUX; INFRA-RED SOURCE PEAK RESPONSE FROM 850-880 NANOMETERS; TIMES NEW ROMAN, REGULAR, 12 POINT TEXT CAN BE READ AT DISTANCE OF 30 CENTIMETERS IN TOTAL DARKNESS; FIELD OF VIEW NOT LESS THAN 38 TO 42 DEGREES; MAGNIFICATION UNITY (1X) PLUS OR MINUS 4 PERCENT; FOCUS ADJUSTMENT RANGE 25 CENTIMETERS TO INFINITY; 4 PERCENT OR LESS DISTORTION ACROSS FIELD OF VIEW
FEATSpecial FeaturesAUTOMATICALLY SHUTS DOWN WHEN EXPOSED TO LIGHT GREATER THAN OR EQUAL TO 1.5 LUX FOR MORE THAN 15-25 SECONDS, BUT WILL NOT SHUT DOWN IF EXPOSED TO LESS THAN OR EQUAL TO 0.8 LUX FOR MORE THAN 15-25 SECONDS; POWERED BY ONE 1.5VDC AA (SIZE) ALKALINE OR RECHARGEABLE NICKEL CADMIUM BATTERY; LOW BATTERY INDICATOR DISPLAYED IN FIELD OF VIEW WHEN POWER DROPS BELOW 1.05-1.35VDC; POWER DRAIN SHALL NOT EXCEED 150.0 MILLIAMPS WHEN OPERATING; REVERSE POLARITY WILL NOT DAMAGE NVG; AVERAGE TIME BETWEEN FAILURES NOT LESS THAN 6,250 HOURS; NVG REMAINS FUNCTIONAL AT TEMPERATURES RANGING FROM MINUS 19 DEGREES TO PLUS 44 DEGREES CELCIUS (PLUS 70 DEGREES CELCIUS IF STORED)


Back to Top
Back to Top