Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
R248325-2 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON COMPANY | 06845 | ![]() |
R650473-1 | 5 - Replaced / Discontinued | 2 - Production Item | RAYTHEON COMPANY | 06845 | ![]() |
TD-137/GPS | 5 - Replaced / Discontinued | 2 - Production Item | JOINT ELECTRONICS TYPE DESIGNATION | 80058 | ![]() |
R650473-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | BENDIX CORP THE | 06840 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
58 | 5895 | 005397198 | A32200 | 00410 | N | K | B | N | U | 0 | 1 Jan 1963 |
Communication, Detection, and Coherent Radiation Equipment
The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Full Descriptive - Reference Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
B482 | B480 | 3 | C | T | 88 | 1 Aug 1999 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
A Federal Aviation Administration activity is providing depot maintenance support.
For agencies excluded from the DSOR program. Not for DoD Service's use.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 5 | 9 | 5 | 48 | B | R650473-1 | 06840 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Federal Aviation Administration, Oklahoma City, OK 73125
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TU | 0 | 29 Oct 1973 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M | 72D | Z | 9 | A | H | Z | W | 061700 | Z | 34580 | ELEC-APPLIANCES-INSTRUMENTS-NOI |
85
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Department of Transportation, Federal Aviation Administration, ATTN: COE AML-030 TSF BLDG 215 PO BOX 25082, Oklahoma City, OK 73125-0082
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Federal Aviation Administration
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | 53 | 1 | 7,560.0 lbs | 781.000 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | JA | JC | X | DR | 00 | 19 | F | O |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
Floating watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
A-A-3174, plastic sheet, polyolefin, 2 mil
ASTM-D4727, domestic fiberboard used as pads, cells, die cuts or sleeves
As required to protect the item or elements of the package
ASTM-D5168, Class 2, weather resistant triple wall fiberboard box.
No requirement.
Method 50 reusable container
Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGAV | End Item Identification | AN/GPA-27' AN/FPS-20 |
AFSU | Average Life Measurement | NOT RATED |
AGTA | Basic Shape Style | IRREGULAR |
BKFC | External Ac Operating Voltage In Volts | 110.0 NOMINAL SINGLE VOLTAGE |
BKFB | External Dc Operating Voltage In Volts | -150.0 NOMINAL 1ST VOLTAGE ERR-100 |
BKFB | External Dc Operating Voltage In Volts | 120.0 NOMINAL 2ND VOLTAGE ERR-100 |
FTLD | Functional Description | ELECTRONIC GATE; GENERATES RANGE GATE FOR USE IN ELECTRONIC SWITCH SA-4670/GPA-27 |
BHSX | Circuit Construction Type | SOLID STATE |
BJBQ | Operating Ac Frequency In Hertz | 60.0 NOMINAL SINGLE VOLTAGE |
BJBJ | Output Wave Shape | RECTANGULAR |
BHTN | Impedance Rating Per Channel | 1000.000 KILOHMS OUTPUT CHANNEL |
AKNA | Inclosure Type | ENCASED |
AMQY | Installation Design | RACK |
BHTS | Polarity Per Channel | POSITIVE OUTPUT CHANNEL |
BHTP | Pulse Duration Per Channel | 120.000 MICROSECONDS MINIMUM OUTPUT CHANNEL AND 630.000 MICROSECONDS MAXIMUM OUTPUT CHANNEL |
BHTW | Pulse Peak Amplitude Per Channel | 25.000 VOLTS OUTPUT CHANNEL |
BHTT | Pulse Repetition Rate Per Channel | 360.000 PULSES PER SECOND NOMINAL OPERATING CHANNEL |
RDAL | Reference Data And Literature | FIG 220-4, T.O. 31P6-2FPS20-4, TECHNICAL MANUAL, ILLUSTRATED PARTS BREAKDOWN, RADAR SETS AN/FPS-20, PG 576 |
BHTZ | Signal Data Type Per Channel | OUTPUT CHANNEL PULSE |
ABKW | Overall Height | 8.280 INCHES NOMINAL |
ABHP | Overall Length | 23.520 INCHES NOMINAL |
ABMK | Overall Width | 21.640 INCHES NOMINAL |
FAAZ | Phase | SINGLE |
FEAT | Special Features | TD-137/GPS |