Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
0N396986 | 3 - Design Control Reference | 2 - Production Item | NATIONAL SECURITY AGENCY | 98230 | ![]() |
AN/FSQ-148(V) | 5 - Replaced / Discontinued | 2 - Production Item | JOINT ELECTRONICS TYPE DESIGNATION | 80058 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
58 | 5895 | 012487292 | A32200 | 00332 | X | M | 5 | F | N | U | 30 Jan 1987 |
Communication, Detection, and Coherent Radiation Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG may exist but lack of technical data and/or the press of time force temporary use of the partial descriptive or reference method.
MLI (SME) — Demilitarization instructions to be furnished by the Item/Technical Manager.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
S018 | 0 | 0 | 1 Apr 1991 |
Not Established
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 2 | XP | 0N396986 | 98230 | ![]() | ||||||
5 | 2 | 4 | XP | AN/FSQ-148(V) | 80058 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
National Security Agency, Fort George G. Meade, MD 20755-6000
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 21 Feb 1987 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XP |
National Security Agency, Fort George G. Meade, MD 20755-6000
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGTA | Basic Shape Style | RECTANGULAR OR SQUARE |
BKFC | External Ac Operating Voltage In Volts | 115.0 NOMINAL 1ST VOLTAGE |
BKFC | External Ac Operating Voltage In Volts | 220.0 NOMINAL 2ND VOLTAGE |
BKFB | External Dc Operating Voltage In Volts | 24.0 NOMINAL 1ST VOLTAGE |
BKFB | External Dc Operating Voltage In Volts | 48.0 NOMINAL 2ND VOLTAGE |
BHTD | Frequency Adjustment Type | STEPPED |
BHTB | Frequency Per Channel | 1.000 MEGAHERTZ NOMINAL 1ST INPUT CHANNEL AND 1.544 MEGAHERTZ NOMINAL 2ND INPUT CHANNEL AND 5.000 MEGAHERTZ NOMINAL 3RD INPUT CHANNEL |
BHSX | Circuit Construction Type | SOLID STATE |
BJBQ | Operating Ac Frequency In Hertz | 50.0 MINIMUM SINGLE VOLTAGE AND 60.0 MAXIMUM SINGLE VOLTAGE |
FTLD | Functional Description | OPERATES FROM SQUARE OR SINUSOIDAL EXTERNAL REFERENCE SIGNALS,MINIMUM 1 VRMS; ACCEPTS 3 INDEPENDENT REFERENCE INPUTS (1.0,1.544 OR 5.0 MHZ) AND OPERATES 1; 12 OUTPUT CARDS EACH DRIVE 6 OUTPUT LINES TERMINATING IN 100 OHMS;LOW RATE DRIVER CARDS PROVIDE 27 SELECTABLE FREQUENCIES FROM 75 HZ TO 512 KHZ; HIGH RATE DRIVER CARDS PROVIDE4 SELECTABLE FREQUENCIES: 2 FIXED (1.536 & 5.000 MHZ) AND 2 PROGRAMMABLE IN 8 KHZ STEPS FROM 1 MHZ TO 13.336 MHZ |
SUPP | Supplementary Features | LOCK DISTRIBUTION |
BHTN | Impedance Rating Per Channel | 100.000 OHMS 1ST OUTPUT CHANNEL |
BHTN | Impedance Rating Per Channel | 100.000 OHMS 2ND OUTPUT CHANNEL |
BHTF | Individual Step Frequency | 8.0 KILOHERTZ |
AMQY | Installation Design | RACK |
ABKW | Overall Height | 10.500 INCHES NOMINAL |
ABHP | Overall Length | 20.125 INCHES NOMINAL |
ABMK | Overall Width | 8.500 INCHES NOMINAL |
FAAZ | Phase | SINGLE |
FEAT | Special Features | EXTERNAL INPUT CAPABILITY IS CHANGABLEBY PLUG-IN MODULES; CLOCK AMPLIFIER SECTION HAS MINIMUM OF 72 OUTPUTS STRAPPABLE,MAKING OUTPUTS EITHER BALANCED OR UNBALANCED; VISIBLE AND AUDIBLE ALARM INDICATES FAILURE OF ANY MAJOR COMPONENT |