Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
G638746-1 | 1 - Source of Control Reference | 3 - Reparable Item | RAYTHEON COMPANY | 49956 | ![]() |
CSA-958113 | 3 - Design Control Reference | 3 - Reparable Item | CELERITEK INC | 2J873 | ![]() |
Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A vendor's reference (part) number on a source control item, as defined in MIL-STD-100A, which is reparable through the removal, exchange, and reinstallation of component parts. The related source control document number will also reflect the code 3. This code is limited to a type 1B or 4B item identification.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
58 | 5895 | 015205664 | A32200 | 00329 | S | N | 5 | B | N | B | A | 0 | 17 May 2004 |
Communication, Detection, and Coherent Radiation Equipment
The item is a non-aviation Critical Safety Item (CSI) whose failure will result in serious damage to equipment or serious injury or death to personnel.
Partial Descriptive - Reference - Descriptive Item Identification (Type 1B Concept)
An approved item name and FIIG may exist but lack of technical data and/or the press of time force temporary use of the partial descriptive or reference method.
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Represents items with ESD sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N2H4 | 2 | H | P | E | CN | GG | 1 May 2004 | |||||||||||||||||||||||
ZC01 | 1 Jan 2005 | |||||||||||||||||||||||||||||
ZG01 | 1 Jul 2005 | |||||||||||||||||||||||||||||
ZH01 | 1 Mar 2010 |
Suitable for competitive acquisition for the first. time. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Total depot maintenance is being accomplished by commercial contract.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Contract, Contiguous United States (CONUS)
Naval Inventory Control Point, Philadelphia, PA 19111û5098
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 1 | HD | G638746-1 | 49956 | ![]() | ||||||
3 | 3 | 5 | HD | CSA-958113 | 2J873 | ![]() |
Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)
A vendor's reference (part) number on a source control item, as defined in MIL-STD-100A, which is reparable through the removal, exchange, and reinstallation of component parts. The related source control document number will also reflect the code 3. This code is limited to a type 1B or 4B item identification.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 19 May 2004 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HD | 72D | Z | 9 | A | H | Z | W | 116030 | Z | 59295 | MACHINES-ETC-DATA-PROCESSING |
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
DIRECT DELIVERY UNDER A CENTRAL CONTRACT # (VENDOR STOCKED) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/Service/Agency supply policy. 1. The item is centrally managed and procured. 2. Normal issue is by direct shipment from the vendor to the user at the order of the ICP or IMM. However, orders may be shipped from stock by ICP or IMM distribution facilities when the vendor's minimum order quantity is not met, or when stocks are being drawn down. 3. Requisitions and fund citations will be submitted in accordance with IMM/Service/Agency Requisitioning Procedures. 4. Generally delivery will be made within applicable Service/Agency guidelines addressing customer required timeframe.
Unclassified
No QUP
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | B | 51 | 1 | 000 |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | JA | GH | H | EC | 00 | O | 03 | E | Q | M |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
Unheated General Purpose
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
A-A-3174, plastic sheet, polyolefin, 2 mil
MIL-PRF-26514, Type I, Class 2, Grade C, flexible polyurethane foam, heavy load range
2 inches thick
ASTM-D5118, Type CF, Class domestic, corrugated fiberboard box.
No requirement.
Unit container is not an acceptable shipping container.
Mehod 50
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGAV | End Item Identification | CONTROLLER MK 32 MOD 0 |
ADZC | Environmental Protection | FUNGUS PROOF AND SALT SPRAY RESISTANT |
BHTB | Frequency Per Channel | 1135.0 MEGAHERTZ MINIMUM 2ND INPUT CHANNEL ERR-100 AND 1205.0 MEGAHERTZ MAXIMUM 2ND INPUT CHANNEL ERR-100 |
BHTB | Frequency Per Channel | -6.0 MEGAHERTZ MINIMUM OUTPUT CHANNEL ERR-100 AND 6.0 MEGAHERTZ MAXIMUM OUTPUT CHANNEL ERR-100 |
BHTB | Frequency Per Channel | 7680.0 MEGAHERTZ MINIMUM 1ST INPUT CHANNEL ERR-100 AND 8352.0 MEGAHERTZ MAXIMUM 1ST INPUT CHANNEL ERR-100 |
AFGA | Operating Temp Range | +0.0/+75.0 DEG CELSIUS |
ZZZY | Reference Number Differentiating Characteristics | AS DIFFERENTIATED BY SOURCE CONTROL DRAWING |
CXCY | Part Name Assigned By Controlling Agency | UPCONVERTER,RADIO FREQUENCY |
FEAT | Special Features | WARNING: THIS PART CONTAINS BERYLLIUM OXIDE (HAZARDOUS) |
AFJQ | Storage Temp Range | -62.0/+75.0 DEG CELSIUS |