5895-01-564-4984

POWER DISTRIBUTION-REFERENCE SIGNAL GROUP


5895-01-564-4984 (5895015644984, 015644984)
Part Number (1 listing): PDS-PDM-100
Summary

FSG 58 / FSC 5895

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 18 Jun 2008

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5895-01-564-4984 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
PDS-PDM-1003 - Design Control Reference2 - Production ItemTACTRONICS GROUP INTERNATIONAL LLC  1RVQ3      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5895-01-564-4984 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
585895015644984A2380017425X46ANAA018 Jun 2008
Code Definitions

58

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Communication, Detection, and Coherent Radiation Equipment

5895

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Miscellaneous Communication Equipment

015644984

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5895-01-564-4984

A23800

Federal Item Identification Guide (FIIG_4065)

17425

Item Naming Code (INC_4080)

18 Jun 2008

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5895-01-564-4984 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZA011 Jun 2008
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5895-01-564-4984 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDPDS-PDM-100  1RVQ3  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5895-01-564-4984 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597018 Jun 2008
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

18 Jun 2008

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5895-01-564-4984 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZA
Code Definitions

ZA

Originating Activity Code (ORIG_ACTY_CD_4210)


Australia

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5895-01-564-4984 Submit RFQ
MRCDecoded RequirementClear Text Reply
BPJZUsage LocationCOMMUNICATIONS ZONE
FEATSpecial FeaturesHOUSING 6061 T6 ALUMINUM. DIMENSIONS; 4.25W X 7.00H X 10.87D INCHES. WEIGHT 11.50 LBS. POWER REQUIREMENTS; 24VDC, POWER USAGE; 80 AMPS AT 24VDC (1920W). PORTS; 1 POWER INPUT, 8 POWER OUTPUT, 1 COMMUNICATIONS. OPERATING TEMP; -20 TO +70 DEGREE C. ALTITUDE 0 TO 10000 FT. PROVIDES CONDITIONED OUTPUT POWER WITH EACH OUTPUT CHANNEL INDIVIDUALLY FUSED. CAPABLE OF INDEPENDENT CONTROL LOCAL OR REMOTELY OVER ETHERNET NETWORK. UNIT IS DRIVEN BY VEHICLE POWER
CXCYPart Name Assigned By Controlling AgencyPOWER DISTRIBUTION MODULE (PDM-100)


Back to Top