Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
3301S1-104 | 3 - Design Control Reference | 9 - No Longer Used | BOURNS INSTRUMENTS INC | 80294 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5905 | 000046214 | A002A0 | 37405 | X | 1 | A | Y | U | 7 Jun 1972 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates information is in the Hazardous Materials Information Resource System (HMIRS).
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR01 | 1 Dec 2007 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 9 | 3 | TX | D | 3301S1-104 | 80294 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 1 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | P | 658 | Z | 9 | A | H | Z | P | 062960 | X | 35140 | REOSTATS-PARTS-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AEFH | Effective Electrical Rotation In Deg Angular Rotation | 300.0 NOMINAL |
CQCC | Electrical Resistance Per Section | 100.000 KILOHMS SINGLE SECTION |
CRSX | Actuator Travel Control Feature | STOPS |
AEFD | Actuator Type | FLUSH DRIVE WITH SLOT-HOLE |
CSDH | Ambient Temp In Deg Celsius Per Section At Full Rated Power | 70.0 SINGLE SECTION |
CQGN | Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power | 175.0 SINGLE SECTION |
ABPM | Body Diameter | 0.310 INCHES NOMINAL |
ADAQ | Body Length | 0.312 INCHES NOMINAL |
AAQL | Body Style | CYLINDRICAL |
AXGY | Mounting Method | TERMINAL |
CRGD | Power Dissipation Rating Per Section In Watts | 0.25 FREE AIR SINGLE SECTION |
AARG | Reliability Indicator | NOT ESTABLISHED |
CRSS | Resistance Tolerance Per Section In Percent | -20.0 TO 20.0 SINGLE SECTION |
CQCK | Rotary Actuator Travel In Angular Deg | 300.0 NOMINAL |
AAPN | Section Quantity | 1 |
APXH | Terminal Location | REAR END |
TTQY | Terminal Type And Quantity | 3 WIRE LOOP |