5905-00-045-6918

RESISTOR,VARIABLE,NONWIRE WOUND,PRECISION


5905-00-045-6918 (5905000456918, 000456918)
Part Numbers (4 listings): 757-6216 | 60802 | 77C707991PT1 | 77C707991P001REVD |
Summary

FSG 59 / FSC 5905

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 13 May 1967

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5905-00-045-6918 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
757-62163 - Design Control Reference2 - Production ItemSENSOR SYSTEMS, L.L.C.  04454    CAGE 04454  
608025 - Replaced / Discontinued9 - No Longer UsedPARMA INDUSTRIES INC  56367      
77C707991PT17 - Vendor Item Drawing Reference2 - Production ItemLOCKHEED MARTIN CORPORATION  03538    CAGE 03538  
77C707991P001REVDC - Advisory Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORPORATION  03538    CAGE 03538  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5905-00-045-6918 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595905000456918A002A037407X1ANA13 May 1967
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5905

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Resistors

000456918

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5905-00-045-6918

A002A0

Federal Item Identification Guide (FIIG_4065)

37407

Item Naming Code (INC_4080)

13 May 1967

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5905-00-045-6918 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YA011 Dec 1999
N9BNN9ND2CZHDHD1 Apr 2006
Code Definitions

2

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition for the first. time. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

C

Acquisition Method Suffix Code (AMSC_2876)


This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

HD

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5905-00-045-6918 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
1321HHD757-6216  04454   CAGE/04454
1591HDB60802  56367  
3721HDD77C707991PT1  03538   CAGE/03538
C16ZZAC77C707991P001REVD  03538   CAGE/03538
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

HH

Reference Number Action Activity Code (RNAAC_2900)


Navy ICP, Mechanicsburg, PA 17055-0788

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

HD

Reference Number Action Activity Code (RNAAC_2900)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

AC

Service / Agency Designator Code (SADC_4672)


Navy


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5905-00-045-6918 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX03 Sep 1982
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3 Sep 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5905-00-045-6918 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
HH658Z9AHZP062960X35140REOSTATS-PARTS-NOI
Code Definitions

HH

Originating Activity Code (ORIG_ACTY_CD_4210)


Navy ICP, Mechanicsburg, PA 17055-0788

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

062960

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35140

Uniform Freight Classification (UFC_CD_MODF_3040)

REOSTATS-PARTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5905-00-045-6918 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSXU1EA0
DSSMSXU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

X

Acquisition Advice Code (AAC_2507)


SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5905-00-045-6918 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPZZXXX
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
X00QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

XXX

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5905-00-045-6918 Submit RFQ
MRCDecoded RequirementClear Text Reply
AEFHEffective Electrical Rotation In Deg Angular Rotation353.0 MINIMUM AND 358.0 MAXIMUM
CQCCElectrical Resistance Per Section1.0 KILOHMS SINGLE SECTION
CRSXActuator Travel Control FeatureCONTINUOUS MOTION
AEFDActuator TypeSINGLE SHAFT
CSDHAmbient Temp In Deg Celsius Per Section At Full Rated Power25.0 SINGLE SECTION
CQGNAmbient Temp In Deg Celsius Per Section At Zero Percent Rated Power150.0 SINGLE SECTION
ABPMBody Diameter1.747 INCHES MINIMUM AND 1.750 INCHES MAXIMUM
ADAQBody Length1.044 INCHES NOMINAL
AAQLBody StyleCYLINDRICAL SERVO MOUNTED
CSBXFunction Characteristic Per SectionSINGLE SECTION LINEAR
CRGMFunction Conformity Per SectionSINGLE SECTION INDEPENDENT LINEARITY
CQFLFunction Conformity Tolerance Per Section-0.30 TO 0.30 SINGLE SECTION
AEFLMaximum Running Torque0.30 INCH-OUNCES
AEFKMaximum Starting Torque0.30 INCH-OUNCES
AEDAMounting Lip Depth0.0900 INCHES MINIMUM
AECZMounting Lip Diameter1.7470 INCHES MINIMUM AND 1.7500 INCHES MAXIMUM
AXGYMounting MethodCLAMP RING
ADAVOverall Diameter1.919 INCHES MINIMUM AND 1.922 INCHES MAXIMUM
ABHPOverall Length1.853 INCHES MINIMUM AND 1.921 INCHES MAXIMUM
AEGALateral Runout0.002 INCHES
CRGDPower Dissipation Rating Per Section In Watts4.0 FREE AIR SINGLE SECTION
AARGReliability IndicatorNOT ESTABLISHED
CRSSResistance Tolerance Per Section In Percent-10.0/+10.0 SINGLE SECTION
CQCKRotary Actuator Travel In Angular Deg360.0 NOMINAL
AAPNSection Quantity1
AEDZShaft Bearing TypeBALL
ABWVShaft Diameter0.187 INCHES NOMINAL
AEFZShaft Runout0.001 INCHES
AEDXShaft StyleROUND
ABXFShaft Length0.843 INCHES MINIMUM AND 0.916 INCHES MAXIMUM
AEGBPilot Diameter Runout0.001 INCHES
AAVLPilot Diameter1.5615 INCHES MINIMUM AND 1.5620 INCHES MAXIMUM
AAVMPilot Length0.1290 INCHES MINIMUM AND 0.1350 INCHES MAXIMUM
ABPCUndercut Width0.0780 INCHES NOMINAL
ABPAUndercut Diameter1.561 INCHES MINIMUM AND 1.562 INCHES MAXIMUM
ABJTTerminal Length0.172 INCHES NOMINAL
APXHTerminal LocationRADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE
TTQYTerminal Type And Quantity3 TAB, SOLDER LUG


Back to Top
Back to Top