5905-00-076-2102

RESISTOR,THERMAL


5905-00-076-2102 (5905000762102, 000762102)
Part Number (1 listing): TM1/8471K
Summary

FSG 59 / FSC 5905

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5905-00-076-2102 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
TM1/8 471K3 - Design Control Reference9 - No Longer UsedTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
TM1/8 471K5 - Replaced / Discontinued9 - No Longer UsedRAYTHEON COMPANY  96214    CAGE 96214  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5905-00-076-2102 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595905000762102A086A000309X1ANU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5905

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Resistors

000762102

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5905-00-076-2102

A086A0

Federal Item Identification Guide (FIIG_4065)

00309

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5905-00-076-2102 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
N9BNN9ND3HZGHHD1 Apr 2006
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5905-00-076-2102 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
39ETXTM1/8 471K  01295   CAGE/01295
59ETXBTM1/8 471K  96214   CAGE/96214
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5905-00-076-2102 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX07 Aug 1969
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

7 Aug 1969

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5905-00-076-2102 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
658Z9AHZP062960X35140REOSTATS-PARTS-NOI
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

062960

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35140

Uniform Freight Classification (UFC_CD_MODF_3040)

REOSTATS-PARTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5905-00-076-2102 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSJU1EA0
DSSMSJU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5905-00-076-2102 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP410AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00DA000D100QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

0

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


No requirement.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

DA

Wrapping Material Code (WRAP_MAT_CD_5163)


A-A-1249, paper, tissue

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

D1

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566 or PPP-B-676, folding or setup box.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5905-00-076-2102 Submit RFQ
MRCDecoded RequirementClear Text Reply
AEHYAmbient Temp At Full Rated Power100.0 DEG CELSIUS
ADAQBody Length0.390 INCHES MINIMUM AND 0.420 INCHES MAXIMUM
ADARBody Outside Diameter0.125 INCHES MINIMUM AND 0.155 INCHES MAXIMUM
AEHZMaximum Operating Temp125.0 DEG CELSIUS
AEHXMaximum Power Dissipation Rating125.00 MILLIWATTS
CQWDZero Power Resistance470.000 OHMS
AKNAInclosure TypeENCAPSULATED
AEJBPower Dissipation Constant In Milliwatts Per Deg Celsius2.5
AARGReliability IndicatorNOT ESTABLISHED
AEJFResistance Tolerance At A Specified Temp In Percent-12.1/+12.1 6TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-12.8 TO 12.8 4TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-14.3 TO 14.3 7TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-14.6/+14.6 3RD RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-15.0 TO 15.0 2ND RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-16.2/+16.2 8TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-16.1/+16.1 1ST RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-18.5 TO 18.5 9TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-20.0/+20.0 10TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-10.3/+10.3 5TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp1.0 KILOHMS 10TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp211.5 OHMS 1ST RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp766.1 OHMS 8TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp916.5 OHMS 9TH RESISTANCE-TEMPERATURE POINT
CRQJZero Power Resistance Tolerance In Percent At Reference Temp-10.0/+10.0
AEJCZero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius0.70
AEJEZero Power Resistance At Specified Temp230.3 OHMS 2ND RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp263.2 OHMS 3RD RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp319.6 OHMS 4TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp390.1 OHMS 5TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp554.6 OHMS 6TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp658.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT
STYLStyle DesignatorROD
AEJDTemp Points For Resistance Readings At Zero Power-25.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power-50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power-75.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power-65.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power0.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power125.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power50.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power75.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
AEBTTerminal Diameter0.025 INCHES NOMINAL
ABJTTerminal Length1.000 INCHES MINIMUM
TTQYTerminal Type And Quantity2 WIRE LEAD
AEJAThermal Time Constant In Seconds35.0


Back to Top